OSHA SearchOSHA records by employer

Williams Ready Mix Products, Inc.: OSHA inspections and violations

Monroe, North Carolina · Ready-Mix Concrete Manufacturing · NAICS 327320

3inspections
15citation items
$300current penalties
May 24, 2016last inspection

OSHA has inspected Williams Ready Mix Products, Inc. 3 times in North Carolina since 2003.

The latest one began on May 24, 2016 as a planned inspection, in Monroe.

Those inspections ended with 15 citation items: 1 serious and 14 other-than-serious.

Penalties were first proposed at $300 and still stand at $300.

Portable fire extinguishers comes up most often in these citations: 3 items under 1910.157.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Williams Ready Mix Products, Inc. averages $300 (1 cited inspection).

Williams Ready Mix Products, Inc.: OSHA citation items per year, 2003 to 2016
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Williams Ready Mix Products, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341501161 OPENED MAY 24, 2016Closed

Planned · Complete · Health · 15 employees at the site · Closed Jul 29, 2016

2465 Charlotte Avenue North, Monroe, NC 28110 · Ready-Mix Concrete Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$300$300Jun 14, 2016Final
Citation 2, item 1a
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$0$0Jun 14, 2016Final
Citation 2, item 1b
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Jun 14, 2016Final
Citation 2, item 2
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Jun 14, 2016Final
Citation 2, item 3
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Jun 14, 2016Final
Citation 2, item 4
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Other-than-serious$0$0Jun 14, 2016Final

Inspection 312257108 OPENED MAY 8, 2008Closed

Planned · Complete · Health · 16 employees at the site · Closed Jun 30, 2008

2465 Old Charlotte Hwy, Monroe, NC 28110 · Ready-Mix Concrete Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0May 30, 2008Closed
Citation 1, item 2
29 CFR 1910.23(e)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0May 30, 2008Closed
Citation 1, item 3
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$0$0May 30, 2008Closed
Citation 1, item 4
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0May 30, 2008Closed
Citation 1, item 5
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0May 30, 2008Closed
Citation 1, item 6
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0May 30, 2008Closed
Citation 1, item 7
29 CFR 1910.253(b)(4)(i) · Gas welding and cutting
Other-than-serious$0$0May 30, 2008Closed
Citation 1, item 8
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0May 30, 2008Closed
Citation 1, item 9
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0May 30, 2008Closed

Inspection 306250101 OPENED JAN 9, 2003Closed

Planned · Partial · Health · 15 employees at the site · Closed Jan 9, 2003

2465 Old Charlotte Hwy, Monroe, NC 28110 · Ready-Mix Concrete Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(b)(2)(vii)(c)(6)

(vi) Vent piping for aboveground tanks. (a) Vent piping shall be constructed in accordance with paragraph (c) of this section.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(5)(i)

(5) Transportation. (i) Chemical manufacturers, importers, or distributors shall ensure that each container of hazardous chemicals leaving the workplace is labeled, tagged, or marked in accordance with this section in a manner which does not conflict with the requirements of the Hazardous Materials Transportation Act (49 U.S.C. 5101 et seq.) and regulations issued under that Act by the Department of Transportation (49 CFR subtitle B).

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.151(c)

(c) Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

Other ready-mix concrete manufacturing employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.