OSHA SearchOSHA records by employer

Wilmar Construction Company, Inc.: OSHA inspections and violations

Vidalia, Louisiana · Commercial and Institutional Building Construction · NAICS 236220

7inspections
12citation items
$2,260current penalties
Jun 8, 2016last inspection

Since 2005, OSHA inspectors have visited Wilmar Construction Company, Inc. in Louisiana 7 times.

The most recent inspection opened on Jun 8, 2016 as a planned inspection, in Vidalia.

In all, OSHA issued 12 citation items: 5 serious and 7 other-than-serious.

The proposed penalties came to $3,100; today they stand at $2,260, 27% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Wilmar Construction Company, Inc. averages $1,080 across 1 cited inspection.

Wilmar Construction Company, Inc.: OSHA citation items per year, 2005 to 2016
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

18employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch Wilmar Construction Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341538692 OPENED JUN 8, 2016Closed

Planned · Complete · Safety · 4 employees at the site · Closed Sep 14, 2016

101 N. Spruce Street, Vidalia, LA 71373 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$1,800$1,080Jul 12, 2016Final
Citation 2, item 1
29 CFR 1926.50(d)(2) · Medical services and first aid
Other-than-serious$0$0Jul 12, 2016Final

Inspection 339032187 OPENED APR 25, 2013Closed

Planned · Partial · Safety · 15 employees at the site · Closed May 1, 2013

406 Lake Street, Lake Providence, LA 71254 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314766775 OPENED AUG 9, 2010Closed

Planned · Partial · Safety · 5 employees at the site · Closed Dec 21, 2010

La Hwy 84/425, Vidalia, LA 71373 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$625$625Oct 28, 2010Closed
Citation 2, item 1
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Oct 28, 2010Closed

Inspection 313025561 OPENED AUG 19, 2009Closed

Planned · Partial · Safety · 2 employees at the site · Closed Mar 22, 2010

Carter Street, Vidalia, LA 71373 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$300$180Sep 16, 2009Closed

Inspection 310247424 OPENED DEC 5, 2006Closed

Planned · Complete · Safety · 3 employees at the site · Closed Dec 5, 2006

2201 Murray Drive, Vidalia, LA 71373 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309085892 OPENED APR 27, 2006Closed

Planned · No inspection · Safety · Closed Apr 27, 2006

2201 Murray Drive, Vidalia, LA 71373 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309078590 OPENED JUL 19, 2005Closed

Planned · Complete · Safety · 3 employees at the site · Closed Nov 2, 2005

2201 Murray Drive, Vidalia, LA 71373 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Serious$375$375Aug 26, 2005Closed
Citation 1, item 1b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Aug 26, 2005Closed
Citation 2, item 1a
29 CFR 1926.403(h) · Electrical equipment on job sites
Other-than-serious$0$0Aug 26, 2005Closed
Citation 2, item 1b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Aug 26, 2005Closed
Citation 2, item 1c
29 CFR 1926.405(b)(1) · Job-site wiring
Other-than-serious$0$0Aug 26, 2005Closed
Citation 2, item 1d
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Aug 26, 2005Closed
Citation 2, item 1e
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$0$0Aug 26, 2005Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(h)

(h) Identification of disconnecting means and circuits. Each disconnecting means required by this subpart for motors and appliances shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. These markings shall be of sufficient durability to withstand the environment involved.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other commercial and institutional building construction employers in Louisiana

Alert subscribers get notified of each newly cited employer in Louisiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.