OSHA SearchOSHA records by employer

Wilsey Roofing & Home Improvements: OSHA inspections and violations

Mechanicsville, Virginia · Roofing Contractors · NAICS 238160

3inspections
8citation items
$3,015current penalties
Oct 8, 2015last inspection

Since 2008, OSHA inspectors have visited Wilsey Roofing & Home Improvements in Virginia 3 times.

The most recent inspection opened on Oct 8, 2015 as a planned inspection, in Gainesville.

In all, OSHA issued 8 citation items: 7 serious and 1 other-than-serious.

The proposed penalties came to $4,050; today they stand at $3,015, 26% less.

The rule cited most here is 1926.501 (fall protection in construction), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Wilsey Roofing & Home Improvements averages $578 across 1 cited inspection.

Wilsey Roofing & Home Improvements: OSHA citation items per year, 2008 to 2015
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

256employers cited

23 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Wilsey Roofing & Home Improvements and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340974252 OPENED OCT 8, 2015Closed

Planned · Partial · Safety · 3 employees at the site · Closed Dec 22, 2015

14800 Lee Highway, Gainesville, VA 20155 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$825$578Dec 10, 2015Final
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Dec 10, 2015Final

Inspection 316972181 OPENED MAR 19, 2013Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jul 10, 2013

Spotsylvania Baptist Church, Lafayette Blvd., Spotsylvania, VA 22553 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$525$368Jun 18, 2013Closed
Citation 1, item 1b
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$0$0Jun 18, 2013Closed
Citation 1, item 2a
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$2,100$1,470Jun 18, 2013Closed
Citation 1, item 2b
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$0$0Jun 18, 2013Closed

Inspection 312564602 OPENED AUG 23, 2008Closed

Planned · Partial · Safety · 3 employees at the site · Closed Oct 10, 2008

6340 Mechanicsville Tnpk., New 7/11 Store, Mechanicsville, VA 23111 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$225$225Sep 10, 2008Closed
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$375$375Sep 10, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(e)(1)

(e) Cords and cables. (1) Worn or frayed electric cords or cables shall not be used.