OSHA SearchOSHA records by employer

Wilston Enterprises Inc.: OSHA inspections and violations

Jamestown, New York · Welding and Soldering Equipment Manufacturing · NAICS 333992

1inspections
6citation items
$7,924current penalties
Aug 12, 2022last inspection

OSHA has inspected Wilston Enterprises Inc. once in New York.

The inspection began on Aug 12, 2022 as a planned inspection, in Jamestown.

That inspection ended with 6 citation items: 4 serious and 2 other-than-serious.

Penalties were first proposed at $10,566 and now stand at $7,924, 25% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 5 items under 1910.147.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Wilston Enterprises Inc. averages $7,924 (1 cited inspection).

Wilston Enterprises Inc.: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Wilston Enterprises Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346143837 OPENED AUG 12, 2022Closed

Planned · Partial · Safety · 13 employees at the site · Closed Sep 19, 2022

121 Jackson Avenue, Jamestown, NY 14701 · Welding and Soldering Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$3,522$2,642Aug 26, 2022Final
Citation 1, item 1b
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Serious$0$0Aug 26, 2022Final
Citation 1, item 2
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$3,522$2,642Aug 26, 2022Final
Citation 1, item 3
29 CFR 1910.147(f)(3)(i) · Lockout/tagout
Serious$3,522$2,642Aug 26, 2022Final
Citation 2, item 1
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Aug 26, 2022Final
Citation 2, item 2
29 CFR 1910.147(e)(3) · Lockout/tagout
Other-than-serious$0$0Aug 26, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.147(c)(7)(i)(a)

(A) Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.

29 CFR 1910.303 · Electrical equipment, general requirements

Other welding and soldering equipment manufacturing employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.