OSHA SearchOSHA records by employer

Winchester Utilities - Administration: OSHA inspections and violations

Winchester, Tennessee · Electric Power Distribution · NAICS 221122

2inspections
5citation items
$0current penalties
Mar 25, 2025last inspection

OSHA has inspected Winchester Utilities - Administration 2 times in Tennessee since 2016.

The latest one began on Mar 25, 2025 as a planned inspection, in Winchester.

Those inspections ended with 5 citation items: 5 serious.

None of the citations carried a penalty.

Electrical wiring methods comes up most often in these citations: 4 items under 1910.305.

How that compares: the median penalty per cited inspection for utility employers since 2015 is $0, and Winchester Utilities - Administration averages $0 (2 cited inspections).

Winchester Utilities - Administration: OSHA citation items per year, 2016 to 2025
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

342employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Winchester Utilities - Administration and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348133232 OPENED MAR 25, 2025Closed

Planned · Complete · Safety · Local government · 15 employees at the site · Closed May 23, 2025

219 2nd Avenue Nw, Winchester, TN 37398 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$0$0Apr 28, 2025Final
Citation 1, item 2
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$0$0Apr 28, 2025Final

Inspection 341650778 OPENED JUL 26, 2016Closed

Planned · Complete · Safety · Local government · 11 employees at the site · Closed Aug 23, 2016

219 2nd Avenue Nw, Winchester, TN 37398 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0Aug 9, 2016Final
Citation 1, item 2
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Serious$0$0Aug 9, 2016Final
Citation 1, item 3
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$0$0Aug 9, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(1)(ii)

(ii) Unused openings in cabinets, boxes, and fittings shall be effectively closed.

29 CFR 1910.305(g)(1)(iv)

(iv) Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used:

Other electric power distribution employers in Tennessee