OSHA SearchOSHA records by employer

Winegard Energy Inc.: OSHA inspections and violations

Park City, Utah · New Housing For-Sale Builders · NAICS 236117

2inspections
3citation items
$1,350current penalties
May 15, 2023last inspection

OSHA has inspected Winegard Energy Inc. 2 times in Utah since 2022.

The latest one began on May 15, 2023 to follow up on an earlier case, in Park City.

Those inspections ended with 3 citation items: 3 serious.

Penalties were first proposed at $1,350 and still stand at $1,350.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Winegard Energy Inc. averages $1,350 (1 cited inspection).

Winegard Energy Inc.: OSHA citation items per year, 2022 to 2023
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

73employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Winegard Energy Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346703374 OPENED MAY 15, 2023Closed

Follow-up · Partial · Safety · 1 employee at the site · Closed May 16, 2023

385 W Goshawk Ranch Rd., Park City, UT 84098 · New Housing For-Sale Builders · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346328644 OPENED NOV 3, 2022Open

Accident · Partial · Safety · 1 employee at the site · Open

385 W Goshawk Ranch Rd., Park City, UT 84098 · New Housing For-Sale Builders · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$450$450Feb 23, 2023Final
Citation 1, item 2
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$450$450Feb 23, 2023Final
Citation 1, item 3
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$450$450Feb 23, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(1)

(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

Other new housing for-sale builders employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.