Inspection 317861441 OPENED JAN 6, 2015Closed
8015 Pendleton Pike, Indianapolis, IN 46226 · Telecommunications · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Indianapolis, Indiana · Telecommunications · NAICS 517210
OSHA has inspected Wireless PCS dba Metro PCS 7 times in Indiana since 2015.
The latest one began on Jan 6, 2015 after a complaint, in Indianapolis.
Those inspections ended with 9 citation items: 9 serious.
Penalties were first proposed at $3,525 and now stand at $2,396, 32% lower after settlements or reviews.
Electrical equipment, general requirements comes up most often in these citations: 6 items under 1910.303.
How that compares: the median penalty per cited inspection for media and telecom employers since 2015 is $1,800, and Wireless PCS dba Metro PCS averages $399 (6 cited inspections).
Indiana · latest 90 days of OSHA records
79employers cited
Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Indiana
Checking a subcontractor, a client or your own company? Watch Wireless PCS dba Metro PCS and get notified the morning OSHA posts a new citation for it.
Watch this company8015 Pendleton Pike, Indianapolis, IN 46226 · Telecommunications · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3850 North Post, Indianapolis, IN 46226 · Telecommunications · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $525 | $341 | May 19, 2015 | Closed |
7023 Pendleton Pike, Indianapolis, IN 46226 · Telecommunications · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.36(d)(1) · Exit route design |
Serious | $300 | $195 | May 19, 2015 | Closed |
| Citation 1, item 2 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $525 | $341 | May 19, 2015 | Closed |
6025 East 34th Street, Indianapolis, IN 46226 · Telecommunications · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $525 | $341 | Jun 11, 2015 | Closed |
| Citation 1, item 2a 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Serious | $525 | $341 | Jun 11, 2015 | Closed |
| Citation 1, item 2b 29 CFR 1910.305(g)(1)(iv)(c) · Electrical wiring methods |
Serious | $0 | $0 | Jun 11, 2015 | Closed |
3637 East 38th Street, Indianapolis, IN 46218 · Telecommunications · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $300 | $300 | May 15, 2015 | Open |
3801 East 10th Street, Indianapolis, IN 46201 · Telecommunications · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $525 | $341 | May 22, 2015 | Closed |
667 East 38th Street, Indianapolis, IN 46205 · Telecommunications · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $300 | $195 | Jun 11, 2015 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.303(b)(2)
(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.
29 CFR 1910.305(g)(1)(iv)(a)
(A) As a substitute for the fixed wiring of a structure;
29 CFR 1910.305(g)(1)(iv)(c)
(C) Where run through doorways, windows, or similar openings;