OSHA SearchOSHA records by employer

Withrow - Young Masonary Inc: OSHA inspections and violations

Lexington, Kentucky · Masonry Contractors · NAICS 238140

1inspections
3citation items
$8,400current penalties
Jun 3, 2024last inspection

OSHA inspectors have visited Withrow - Young Masonary Inc in Kentucky one time.

It opened on Jun 3, 2024 as part of a related case, in Lexington and is still open.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $10,500; today they stand at $8,400, 20% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Withrow - Young Masonary Inc averages $8,400 across 1 cited inspection.

Withrow - Young Masonary Inc: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Kentucky · latest 90 days of OSHA records

189employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Kentucky: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Kentucky

Checking a subcontractor, a client or your own company? Watch Withrow - Young Masonary Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347522294 OPENED JUN 3, 2024Open

Unprogrammed related · Partial · Safety · 9 employees at the site · Open

120 Lucille Drive, Lexington, KY 40511 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$3,500$2,500Oct 30, 2024Final
Citation 1, item 2
29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements
Serious$3,500$2,500Oct 30, 2024Final
Citation 1, item 3
29 CFR 1926.706(b) · Requirements for masonry construction
Serious$3,500$3,400Oct 30, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(g)(1)(vi)

(vi) Each employee performing overhand bricklaying operations from a supported scaffold shall be protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity).

29 CFR 1926.706 · Requirements for masonry construction

29 CFR 1926.706(b)

(b) All masonry walls over eight feet in height shall be adequately braced to prevent overturning and to prevent collapse unless the wall is adequately supported so that it will not overturn or collapse. The bracing shall remain in place until permanent supporting elements of the structure are in place.

Other masonry contractors employers in Kentucky

Alert subscribers get notified of each newly cited employer in Kentucky the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.