OSHA SearchOSHA records by employer

WM Home Solutions LLC: OSHA inspections and violations

Glen Burnie, Maryland · Siding Contractors · NAICS 238170

1inspections
7citation items
$1,400current penalties
Dec 10, 2025last inspection

OSHA has inspected WM Home Solutions LLC once in Maryland.

The inspection began on Dec 10, 2025 as a planned inspection, in Glen Burnie; the case is still open.

That inspection ended with 7 citation items: 7 serious.

Penalties were first proposed at $1,400 and still stand at $1,400.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and WM Home Solutions LLC averages $1,400 (1 cited inspection).

WM Home Solutions LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

187employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch WM Home Solutions LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348636093 OPENED DEC 10, 2025Open

Planned · Complete · Safety · 2 employees at the site · Open

1028 4th Street, Glen Burnie, MD 21060 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,400$1,400Jan 21, 2026Final
Citation 1, item 1b
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$0$0Jan 21, 2026Final
Citation 1, item 1c
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Jan 21, 2026Final
Citation 1, item 1d
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Jan 21, 2026Final
Citation 1, item 1e
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$0$0Jan 21, 2026Final
Citation 1, item 1f
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Jan 21, 2026Final
Citation 1, item 1g
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Jan 21, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(c)(3)

(3) Supported scaffold poles, legs, posts, frames, and uprights shall be plumb and braced to prevent swaying and displacement.

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training