OSHA SearchOSHA records by employer

Wolf Siding & Windows: OSHA inspections and violations

Pewaukee, Wisconsin · Siding Contractors · NAICS 238170

4inspections
17citation items
$10,867current penalties
Jun 5, 2018last inspection

Since 2003, OSHA inspectors have visited Wolf Siding & Windows in Wisconsin 4 times.

The most recent inspection opened on Jun 5, 2018 as a planned inspection, in Oconomowoc.

In all, OSHA issued 17 citation items: 5 serious, 3 repeat and 9 other-than-serious.

The proposed penalties came to $36,601; today they stand at $10,867, 70% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Wolf Siding & Windows averages $5,224 across 2 cited inspections.

Wolf Siding & Windows: OSHA citation items per year, 2003 to 2018
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

229employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Wolf Siding & Windows and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343212163 OPENED JUN 5, 2018Closed

Planned · Partial · Safety · 8 employees at the site · Closed Aug 30, 2019

1650 Brown St., Oconomowoc, WI 53066 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(3) · Scaffolds, general requirements
Other-than-serious$1,663$0Jun 28, 2018Final
Citation 1, item 2a
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Other-than-serious$1,663$0Jun 28, 2018Final
Citation 1, item 2b
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Other-than-serious$0$0Jun 28, 2018Final
Citation 1, item 3a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Other-than-serious$2,772$0Jun 28, 2018Final
Citation 1, item 3b
29 CFR 1926.454(b) · Scaffold training
Other-than-serious$0$0Jun 28, 2018Final
Citation 1, item 4
29 CFR 1926.452(k)(5) · Rules for each type of scaffold
Other-than-serious$1,663$0Jun 28, 2018Final
Citation 1, item 5
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$3,880$1,520Jun 28, 2018Final
Citation 2, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$7,760$3,000Jun 28, 2018Final
Citation 2, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Repeat$5,543$3,000Jun 28, 2018Final
Citation 2, item 3
29 CFR 1926.1060(a) · Ladder and stairway training
Repeat$5,543$0Jun 28, 2018Final
Citation 3, item 1
29 CFR 1903.19(d)(1) · Proving cited hazards were fixed
Other-than-serious$319$319Feb 7, 2019Final

Inspection 342505351 OPENED JUL 26, 2017Closed

Planned · Partial · Safety · 2 employees at the site · Closed Aug 30, 2019

11028 N. Mequon Square Dr., Mequon, WI 53092 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,630$1,304Sep 15, 2017Final
Citation 1, item 2a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,630$1,304Sep 15, 2017Final
Citation 1, item 2b
29 CFR 1926.1060(a) · Ladder and stairway training
Serious$1,630$0Sep 15, 2017Final
Citation 2, item 1
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$305$0Nov 16, 2017Final

Inspection 308379841 OPENED APR 26, 2005Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jul 12, 2005

305 Market Street, Watertown, WI 53094 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$600$420May 10, 2005Closed
Citation 2, item 1
29 CFR 1926.454(a) · Scaffold training
Other-than-serious$0$0May 10, 2005Closed

Inspection 305280216 OPENED OCT 2, 2003Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Nov 19, 2003

1088 Quail Ct., Pewaukee, WI 53072 · Siding Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(c)(1)

(c) Abatement certification. (1) Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.

29 CFR 1903.19(d)(1)

(d) Abatement documentation. (1) The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other siding contractors employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.