OSHA SearchOSHA records by employer

Woll Construction, LLC: OSHA inspections and violations

Newport, Rhode Island · Residential Remodelers · NAICS 236118

1inspections
3citation items
$8,192current penalties
Sep 25, 2020last inspection

Woll Construction, LLC has one OSHA inspection on record in Rhode Island.

OSHA opened it on Sep 25, 2020 as a planned inspection, in Newport.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $8,192 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Woll Construction, LLC averages $8,192 over 1 cited inspection in that time.

Woll Construction, LLC: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Rhode Island · latest 90 days of OSHA records

84employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Rhode Island

Checking a subcontractor, a client or your own company? Watch Woll Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344944327 OPENED SEP 25, 2020Closed

Planned · Partial · Safety · 3 employees at the site · Closed Aug 27, 2025

24 Merton Rd., Newport, RI 02840 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$4,096$4,096Feb 11, 2021Final
Citation 1, item 1b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Feb 11, 2021Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,096$4,096Feb 11, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

Other residential remodelers employers in Rhode Island

Alert subscribers get notified of each newly cited employer in Rhode Island the morning it is posted. See the alert plans.