OSHA SearchOSHA records by employer

Wood Design Inc.: OSHA inspections and violations

Santa Fe, New Mexico · Wood Office Furniture Manufacturing · NAICS 337211

5inspections
14citation items
$575current penalties
Mar 5, 2020last inspection

Wood Design Inc. has 5 OSHA inspections on record in New Mexico, the first in 1999.

OSHA's last visit started on Mar 5, 2020, in Santa Fe.

Across those inspections OSHA issued 14 citation items: 4 serious and 10 other-than-serious.

OSHA proposed $2,275 in penalties. After settlements and reviews the total is $575, down 75%.

Most often, OSHA cited 1910.134, respiratory protection (6 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Wood Design Inc. averages $0 over 1 cited inspection in that time.

Wood Design Inc.: OSHA citation items per year, 1999 to 2020
Citation items per year, by inspection date.

New Mexico · latest 90 days of OSHA records

31employers cited

Get notified the morning OSHA posts each new citation in New Mexico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Mexico

Checking a subcontractor, a client or your own company? Watch Wood Design Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344676010 OPENED MAR 5, 2020Closed

Unprogrammed other · Complete · Safety · 26 employees at the site · Closed Feb 24, 2021

1091 Siler Road, Santa Fe, NM 87507 · Custom Architectural Woodwork and Millwork Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.4(a) · Recording criteria
Other-than-serious$0$0Aug 25, 2020Final
Citation 1, item 2
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Aug 25, 2020Final

Inspection 313697153 OPENED OCT 14, 2009Closed

Planned · Complete · Safety · 13 employees at the site · Closed Mar 1, 2010

1242 Siler Road Ste. 9, Santa Fe, NM 87505 · Wood Office Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$800$0Nov 23, 2009Final
Citation 1, item 2
29 CFR 1910.213(o)(4) · Woodworking machinery
Serious$800$400Nov 20, 2009Final

Inspection 311570261 OPENED DEC 14, 2007Closed

Planned · Complete · Health · 16 employees at the site · Closed Feb 6, 2008

1242 Siler Road Ste. 9, Santa Fe, NM 87505 · Wood Office Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$75$75Jan 25, 2008Closed

Inspection 305242653 OPENED JAN 7, 2004Closed

Planned · Complete · Health · 14 employees at the site · Closed Jan 16, 2004

1242 Siler Road Ste. 9, Santa Fe, NM 87505 · Wood Office Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302267133 OPENED MAR 16, 1999Closed

Planned · Complete · Safety · 14 employees at the site · Closed Jul 14, 1999

1242 Siler Road Ste. 9, Santa Fe, NM 87505 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$300$50Apr 29, 1999Closed
Citation 1, item 2
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$300$50Apr 29, 1999Closed
Citation 2, item 1
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Other-than-serious$0$0Apr 29, 1999Closed
Citation 2, item 2
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Apr 29, 1999Closed
Citation 2, item 3
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Apr 29, 1999Closed
Citation 2, item 4
29 CFR 1910.134(f)(2) · Respiratory protection
Other-than-serious$0$0Apr 29, 1999Closed
Citation 2, item 5
29 CFR 1910.134(k)(1)(i) · Respiratory protection
Other-than-serious$0$0Apr 29, 1999Closed
Citation 2, item 6
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Apr 29, 1999Closed
Citation 2, item 7
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Apr 29, 1999Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.4 · Recording criteria

29 CFR 1904.4(a)

(a) Basic requirement. Each employer required by this part to keep records of fatalities, injuries, and illnesses must record each fatality, injury and illness that:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(d)(1)(iii)

(iii) The employer shall identify and evaluate the respiratory hazard(s) in the workplace; this evaluation shall include a reasonable estimate of employee exposures to respiratory hazard(s) and an identification of the contaminant's chemical state and physical form. Where the employer cannot identify or reasonably estimate the employee exposure, the employer shall consider the atmosphere to be IDLH.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.305 · Electrical wiring methods

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.