OSHA SearchOSHA records by employer

Wood-Fire Roasted Coffee Company LLC: OSHA inspections and violations

Reno, Nevada · Coffee and Tea Manufacturing · NAICS 311920

1inspections
5citation items
$2,264current penalties
Sep 11, 2024last inspection

Wood-Fire Roasted Coffee Company LLC has one OSHA inspection on record in Nevada.

OSHA opened it on Sep 11, 2024 as a planned inspection, in Reno.

From that inspection OSHA issued 5 citation items: 2 serious and 3 other-than-serious.

OSHA proposed $4,528 in penalties. After settlements and reviews the total is $2,264, down 50%.

Most often, OSHA cited 1910.305, electrical wiring methods (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,874. Wood-Fire Roasted Coffee Company LLC averages $2,264 over 1 cited inspection in that time.

Wood-Fire Roasted Coffee Company LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Nevada · latest 90 days of OSHA records

113employers cited

Get notified the morning OSHA posts each new citation in Nevada: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Nevada

Checking a subcontractor, a client or your own company? Watch Wood-Fire Roasted Coffee Company LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347746794 OPENED SEP 11, 2024Closed

Planned · Complete · Safety · 2 employees at the site · Closed Nov 15, 2024

30 Ohm Place Suite 2, Reno, NV 89502 · Coffee and Tea Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$2,765$1,382Oct 17, 2024Final
Citation 1, item 2
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$1,763$882Oct 17, 2024Final
Citation 2, item 1
29 CFR 1910.37(a)(4) · Exit routes
Other-than-serious$0$0Oct 17, 2024Final
Citation 2, item 2
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 17, 2024Final
Citation 2, item 3
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Other-than-serious$0$0Oct 17, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(1)

(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(1)

(1) Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(1)(ii)

(ii) Unused openings in cabinets, boxes, and fittings shall be effectively closed.

29 CFR 1910.37 · Exit routes

Other coffee and tea manufacturing employers in Nevada

Alert subscribers get notified of each newly cited employer in Nevada the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.