OSHA SearchOSHA records by employer

Woodco Walls Inc: OSHA inspections and violations

Terre Haute, Indiana · Poured Concrete Foundation and Structure Contractors · NAICS 238110

1inspections
2citation items
$488current penalties
May 7, 2025last inspection

Woodco Walls Inc has one OSHA inspection on record in Indiana.

OSHA opened it on May 7, 2025 as a planned inspection, in Terre Haute.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $750 in penalties. After settlements and reviews the total is $488, down 35%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Woodco Walls Inc averages $488 over 1 cited inspection in that time.

Woodco Walls Inc: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

79employers cited

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch Woodco Walls Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348230442 OPENED MAY 7, 2025Closed

Planned · Partial · Safety · 16 employees at the site · Closed Nov 5, 2025

4722 Harrison Denham Way, Terre Haute, IN 47802 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$300$195Jul 9, 2025Final
Citation 1, item 2
29 CFR 1926.652(a)(1) · Trench protection
Serious$450$292Jul 9, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)

(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:

Other poured concrete foundation and structure contractors employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.