OSHA SearchOSHA records by employer

World Foods LLC: OSHA inspections and violations

Portland, Oregon · Supermarkets and Other Grocery Retailers (except Convenience Retailers) · NAICS 445110

2inspections
10citation items
$540current penalties
Sep 23, 2016last inspection

World Foods LLC has 2 OSHA inspections on record in Oregon, the first in 2016.

OSHA's last visit started on Sep 23, 2016 to follow up on an earlier case, in Portland.

Across those inspections OSHA issued 10 citation items: 3 serious and 7 other-than-serious.

OSHA proposed $540 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.305, electrical wiring methods (3 items).

For context, across all retail employers the median penalty per cited inspection since 2015 is $1,750. World Foods LLC averages $540 over 1 cited inspection in that time.

World Foods LLC: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

391employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch World Foods LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341817229 OPENED SEP 23, 2016Closed

Follow-up · Partial · Safety · 10 employees at the site · Closed Sep 23, 2016

830 Nw Everett St, Portland, OR 97209 · Supermarkets and Other Grocery Retailers (except Convenience Retailers) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341610889 OPENED JUL 11, 2016Closed

Planned · Complete · Safety · 45 employees at the site · Closed Dec 1, 2016

830 Nw Everett St, Portland, OR 97209 · Supermarkets and Other Grocery Retailers (except Convenience Retailers) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$180$180Aug 15, 2016Final
Citation 1, item 2
29 CFR OAR 437-002-0221(4)(A)
Serious$180$180Aug 15, 2016Final
Citation 1, item 3
29 CFR OAR 437-002-2101(2)
Serious$180$180Aug 15, 2016Final
Citation 2, item 4
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Other-than-serious$0$0Aug 15, 2016Final
Citation 2, item 5
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$0$0Aug 15, 2016Final
Citation 2, item 6
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Aug 15, 2016Final
Citation 2, item 7
29 CFR OAR 437-001-0765(1)
Other-than-serious$0$0Aug 15, 2016Final
Citation 2, item 8
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Aug 15, 2016Final
Citation 2, item 9
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Aug 15, 2016Final
Citation 2, item 10
29 CFR OAR 437-002-0187(2)-2
Other-than-serious$0$0Aug 15, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.22 · General requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.304(g)(5)

(5) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.