Inspection 344055827 OPENED JUN 4, 2019Closed
300 Kodak Blvd., Longview, TX 75602 · All Other Miscellaneous Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Worley Parsons has 2 OSHA inspections on record in Texas, the first in 2016.
OSHA's last visit started on Jun 4, 2019 after a complaint, in Longview.
Across those inspections OSHA issued 4 citation items: 4 other-than-serious.
OSHA proposed $37,413 in penalties and the amount has not been reduced.
Most often, OSHA cited 1910.147, lockout/tagout (4 items).
For context, across all professional services employers the median penalty per cited inspection since 2015 is $1,822. Worley Parsons averages $37,413 over 1 cited inspection in that time.
Texas · latest 90 days of OSHA records
391employers cited
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch Worley Parsons and get notified the morning OSHA posts a new citation for it.
Watch this company300 Kodak Blvd., Longview, TX 75602 · All Other Miscellaneous Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
8580 Sheldon Road, Houston, TX 77049 · Engineering Services · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.147(c)(4)(ii)(d) · Lockout/tagout |
Other-than-serious | $12,471 | $12,471 | Nov 9, 2016 | Final |
| Citation 1, item 1b 29 CFR 1910.147(d)(5)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Nov 9, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Other-than-serious | $12,471 | $12,471 | Nov 9, 2016 | Final |
| Citation 1, item 3 29 CFR 1910.147(d)(3) · Lockout/tagout |
Other-than-serious | $12,471 | $12,471 | Nov 9, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.147(c)(4)(ii)(d)
(D) Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.
29 CFR 1910.147(c)(6)(i)
(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.
29 CFR 1910.147(d)(3)
(3) Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s).
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.