OSHA SearchOSHA records by employer

Wright Masonry: OSHA inspections and violations

Savannah, Georgia · Masonry Contractors · NAICS 238140

2inspections
9citation items
$3,673current penalties
Sep 7, 2017last inspection

Wright Masonry has 2 OSHA inspections on record in Georgia, the first in 2006.

OSHA's last visit started on Sep 7, 2017 as a planned inspection, in Cedartown.

Across those inspections OSHA issued 9 citation items: 9 serious.

OSHA proposed $5,784 in penalties. After settlements and reviews the total is $3,673, down 36%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (7 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Wright Masonry averages $2,660 over 1 cited inspection in that time.

Wright Masonry: OSHA citation items per year, 2006 to 2017
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

146employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Wright Masonry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342621026 OPENED SEP 7, 2017Closed

Planned · Complete · Safety · 5 employees at the site · Closed Dec 12, 2018

800 Blanc Road, Cedartown, GA 30125 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Incident on Aug 29, 2017: Worker incurs leg fractures in scaffold collapse

At 1:15 p.m. on August 29, 2017, Employee #1, employed by a masonry company, was engaged in exterior masonry at a two-story multifamily residential building project. He was climbing a scaffold to return to work after lunch. The scaffold tipped over and collapsed, and Employee #1 fell, a fall height of 9 feet. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for multiple fractures of his leg.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(1)(i) · Scaffolds, general requirements
Serious$2,217$1,330Feb 15, 2018Final
Citation 1, item 1b
29 CFR 1926.451(g)(4) · Scaffolds, general requirements
Serious$0$0Feb 15, 2018Final
Citation 1, item 2a
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$2,217$1,330Feb 15, 2018Final
Citation 1, item 2b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Feb 15, 2018Final
Citation 1, item 2c
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Feb 15, 2018Final

Inspection 307413120 OPENED DEC 6, 2006Closed

Planned · Complete · Safety · 4 employees at the site · Closed Oct 28, 2010

29 Tranquil Pl., Lot #4, Savannah, GA 31414 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$225$119Jan 31, 2007Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$300$225Jan 31, 2007Closed
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$525$394Jan 31, 2007Closed
Citation 1, item 4
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$300$275Jan 31, 2007Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(1)(i)

(i) Guys, ties, and braces shall be installed at locations where horizontal members support both inner and outer legs.

29 CFR 1926.451(c)(2)(ii)

(ii) Unstable objects shall not be used to support scaffolds or platform units.

29 CFR 1926.452 · Rules for each type of scaffold

Other masonry contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.