Inspection 343602223 OPENED NOV 15, 2018Closed
4215 Legion Drive, Mason, MI 48854 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
XG Sciences, Inc. has 4 OSHA inspections on record in Michigan, the first in 2011.
OSHA's last visit started on Nov 15, 2018 as a planned inspection, in Mason.
Across those inspections OSHA issued 4 citation items: 3 serious and 1 other-than-serious.
OSHA proposed $2,400 in penalties. After settlements and reviews the total is $1,200, down 50%.
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. XG Sciences, Inc. averages $1,050 over 1 cited inspection in that time.
Michigan · latest 90 days of OSHA records
670employers cited
Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Michigan
Checking a subcontractor, a client or your own company? Watch XG Sciences, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company4215 Legion Drive, Mason, MI 48854 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2100 S Washington Ave, Lansing, MI 48911 · Carbon and Graphite Product Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Aug 9, 2017: Employee catches hand in chain and partially amputates finge
At 6:15 a.m. on August 9, 2017, an employee was trying to diagnose unusual noise occurring on the a mill. The employee was checking the chain tension when a coworker activated the "jog" button, activating the machine. The employee's fingers were caught in the chain and sprocket, resulting in a amputation of the left index finger (to first knuckle) and laceration and stitches were required on left middle finger. The employee was not hospitalized. hospitalized.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $2,100 | $1,050 | Sep 22, 2017 | Final |
3101 Grand Oak Dr, Lansing, MI 48911 · Carbon and Graphite Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2100 S Washington Ave Bldg C, Lansing, MI 48910 · Plastics Material and Resin Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $150 | $75 | Oct 11, 2011 | Closed |
| Citation 1, item 2 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $150 | $75 | Oct 11, 2011 | Closed |
| Citation 2, item 1 | Other-than-serious | $0 | $0 | Oct 11, 2011 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.134(c)(1)
(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.
29 CFR 1910.147(c)(4)(i)
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.