Inspection 347496978 OPENED MAY 20, 2024Closed
220 Clifton Boulevard, Clifton, NJ 07011 · Plastics Bag and Pouch Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Clifton, New Jersey · Plastics Bag and Pouch Manufacturing · NAICS 326111
Since 2016, OSHA inspectors have visited XL Plastics in New Jersey 5 times.
The most recent inspection opened on May 20, 2024 on a referral, in Clifton.
In all, OSHA issued 8 citation items: 6 serious, 1 repeat and 1 other-than-serious.
The proposed penalties came to $75,294; today they stand at $45,082, 40% less.
The rule cited most here is 1910.147 (lockout/tagout), 2 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. XL Plastics averages $11,271 across 4 cited inspections.
It reported 3 severe injuries to OSHA since 2015.
New Jersey · latest 90 days of OSHA records
270employers cited
Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New Jersey
Checking a subcontractor, a client or your own company? Watch XL Plastics and get notified the morning OSHA posts a new citation for it.
Watch this company220 Clifton Boulevard, Clifton, NJ 07011 · Plastics Bag and Pouch Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
220 Clifton Boulevard, Clifton, NJ 07011 · Plastics Bag and Pouch Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.37(a)(3) · Exit routes |
Serious | $13,052 | $7,570 | May 11, 2022 | Final |
| Citation 1, item 2 29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements |
Serious | $7,458 | $4,430 | May 11, 2022 | Final |
220 Clifton Boulevard, Clifton, NJ 07011 · Plastics Bag and Pouch Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Mar 4, 2020: Employee amputates finger on individual folder machine
At 7:45 p.m. on March 4, 2020, an employee was working on an individual folder machine. The employee slipped, and his hand made contact with the gear of the folder machine. The employee amputated the tip of his right index finger and was hospitalized.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(1) · Machine guarding |
Repeat | $20,782 | $10,500 | Jun 22, 2020 | Final |
220 Clifton Boulevard, Clifton, NJ 07011 · Plastics Bag and Pouch Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Apr 12, 2019: Employee fractures arm while clearing jam in plastics extrud
At 1:05 p.m. on April 12, 2019, an employee was working for a firm that manufactured plastic bags and pouches. He was working in a production area. The production area had lines with plastic extrusion machines. Along with a coworker, the employee had the task of changing filters on the machines. On at least one machine, a ram feeder had been added to the extruder or extrusion machine. One of the machines had jammed. Part of the ram, a hammer, was stuck inside. The employee was clearing out the ram when his hand became caught in the machine. He suffered a fracture to the radius in his right arm. He was hospitalized. According to the coworker in an interview later, the machine would become jammed when it was overcome with too much plastic. When this happened, the workers would stop the machine, turn off the air and use an 0.7-meter (2-foot) wooden stick to remove the material stuck in the ram. The ram became stuck with material one to two times per week, depending on the material. Cleaning took about four to five minutes. The machine was cleaned on all shifts, and the coworker cleaned the machine on May 7, 2019. Generally, compressed air was used to clear jammed plastic from the machine. The lockout/tagout program provided by the employer did not have documented training for the employee or his coworker.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1904.39(a)(2) · Reporting deaths and severe injuries |
Other-than-serious | $5,626 | $3,657 | Aug 14, 2019 | Final |
| Citation 1, item 2 29 CFR 1910.147(c)(4)(ii)(b) · Lockout/tagout |
Serious | $9,377 | $6,095 | Aug 14, 2019 | Final |
| Citation 1, item 3 29 CFR 1910.147(c)(7)(i) · Lockout/tagout |
Serious | $9,377 | $6,095 | Aug 14, 2019 | Final |
220 Clifton Boulevard, Clifton, NJ 07011 · Plastics Bag and Pouch Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(a)(1) · General requirements |
Serious | $4,811 | $3,368 | Jan 13, 2017 | Final |
| Citation 1, item 2 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $4,811 | $3,368 | Jan 13, 2017 | Final |
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 3 reports on file.
May 16, 2024, Clifton: Hospitalization · fractures · rib(s), oblique area
An employee fell off a stack of cardboard boxes to the concrete floor, resulting in broken ribs.
Mar 4, 2020, Clifton: Hospitalization, amputation · amputations · fingertip(s)
An employee was working on an individual folder machine. The employee slipped and their hand contacted a gear resulting in amputation of the right index fingertip.
Apr 12, 2019, Clifton: Hospitalization · fractures · forearm(s)
An employee was cleaning the ram on a plastic extruder machine when the employee's hand and arm were caught in the machine causing a fractured right radius.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1904.39(a)(2)
(2) Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA.
29 CFR 1910.134(e)(1)
(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.
29 CFR 1910.147(c)(4)(ii)(b)
(B) Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy;
Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.