OSHA SearchOSHA records by employer

Xtreme Rehabs L.L.C.: OSHA inspections and violations

Methuen, Massachusetts · Siding Contractors · NAICS 238170

1inspections
3citation items
$3,511current penalties
Jul 8, 2021last inspection

OSHA inspectors have visited Xtreme Rehabs L.L.C. in Massachusetts one time.

It opened on Jul 8, 2021 on a referral, in Methuen.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $7,022; today they stand at $3,511, 50% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Xtreme Rehabs L.L.C. averages $3,511 across 1 cited inspection.

Xtreme Rehabs L.L.C.: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

262employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Xtreme Rehabs L.L.C. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345410401 OPENED JUL 8, 2021Closed

Referral · Partial · Safety · 4 employees at the site · Closed Sep 8, 2025

64 Broadway, Methuen, MA 01844 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$2,926$1,463Oct 15, 2021Final
Citation 1, item 2a
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$4,096$2,048Oct 15, 2021Final
Citation 1, item 2b
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$0$0Oct 15, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(2)

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.

Other siding contractors employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.