OSHA has inspected YD Hawaii Construction Corporation once in Hawaii.

The inspection began on Dec 11, 2016 as part of a related case, in Honolulu; the case is still open.

That inspection ended with 7 citation items: 7 serious.

Penalties were first proposed at $11,600 and still stand at $11,600.

Electrical equipment on job sites comes up most often in these citations: 2 items under 1926.403.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and YD Hawaii Construction Corporation averages $11,600 (1 cited inspection).

1 inspection on this page followed a fatal incident.

YD Hawaii Construction Corporation: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Hawaii · latest 90 days of OSHA records

67employers cited

Get notified the morning OSHA posts each new citation in Hawaii: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Hawaii

Checking a subcontractor, a client or your own company? Watch YD Hawaii Construction Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341966679 OPENED DEC 11, 2016Open

Unprogrammed related · Complete · Health · 2 employees at the site · Open

413 Seaside Ave, Honolulu, HI 96815 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Incident on Dec 11, 2016 (fatal): Employee falls from scaffold and is killed

At 5:00 p.m. on December 11, 2016, Employee #1 was standing on a temporary elevated working platform (scaffold) to inspect an air intake ductwork. He used a non-self-supporting ladder to gain access to a wooden plank, measuring 71 1/4 inches in length by 9 1/4 inches in width. The plank rested perpendicularly atop two parallel lengths of angle iron. The scaffold platform was measured to be 10 feet 8 inches above a concrete lower level. Two coworkers working beneath did not observe Employee #1 immediately before he fell. Therefore, it is not known whether he fell from the scaffold platform, or fell while stepping down from the scaffold platform. The two coworkers below recall an 8-foot section of galvanized metal pipe hitting the floor, and bracing themselves in anticipation of other falling objects. The coworkers then looked to their right, where they found Employee #1's body. The employee was killed from craniocerebral injuries due to blunt force head trauma.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 12-110-2(F)(1)(A)
Serious$2,800$2,800Apr 26, 2017Final
Citation 1, item 2
29 CFR 12-110-3(B)
Serious$2,800$2,800Apr 26, 2017Final
Citation 1, item 3a
29 CFR 1926.403(e) · Electrical equipment on job sites
Serious$2,000$2,000Apr 26, 2017Final
Citation 1, item 3b
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$0$0Apr 26, 2017Final
Citation 1, item 3c
29 CFR 1926.405(d) · Job-site wiring
Serious$0$0Apr 26, 2017Final
Citation 1, item 4
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$2,000$2,000Apr 26, 2017Final
Citation 1, item 5
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$2,000$2,000Apr 26, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(e)

(e) Splices. Conductors shall be spliced or joined with splicing devices designed for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soldered splices shall first be so spliced or joined as to be mechanically and electrically secure without solder and then soldered. All splices and joints and the free ends of conductors shall be covered with an insulation equivalent to that of the conductors or with an insulating device designed for the purpose.

29 CFR 1926.403(i)(2)(i)

(2) Guarding of live parts. (i) Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(d)

(d) Switchboards and panelboards. Switchboards that have any exposed live parts shall be located in permanently dry locations and accessible only to qualified persons. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons. Exposed blades of knife switches shall be dead when open.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other commercial and institutional building construction employers in Hawaii

Alert subscribers get notified of each newly cited employer in Hawaii the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.