OSHA SearchOSHA records by employer

Yesac Georgia Corporation: OSHA inspections and violations

Lagrange, Georgia · Fabricated Structural Metal Manufacturing · NAICS 332312

4inspections
8citation items
$23,038current penalties
Jan 10, 2018last inspection

Yesac Georgia Corporation has 4 OSHA inspections on record in Georgia, the first in 2015.

OSHA's last visit started on Jan 10, 2018 on a referral, in Lagrange.

Across those inspections OSHA issued 8 citation items: 8 serious.

OSHA proposed $38,397 in penalties. After settlements and reviews the total is $23,038, down 40%.

Most often, OSHA cited 1910.212, machine guarding (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Yesac Georgia Corporation averages $7,679 over 3 cited inspections in that time.

Yesac Georgia Corporation: OSHA citation items per year, 2015 to 2018
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

150employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Yesac Georgia Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342878055 OPENED JAN 10, 2018Closed

Referral · Partial · Health · 20 employees at the site · Closed Aug 9, 2018

820 Old Hutchinson Mill Road, Lagrange, GA 30240 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$6,467$3,880Jun 18, 2018Final
Citation 1, item 2
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Serious$3,880$2,328Jun 18, 2018Final
Citation 1, item 3
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$6,467$3,880Jun 18, 2018Final
Citation 1, item 4
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$5,174$3,104Jun 18, 2018Final

Inspection 342846854 OPENED DEC 21, 2017Closed

Planned · Partial · Safety · 20 employees at the site · Closed Aug 3, 2018

820 Old Hutchinson Mill Road, Lagrange, GA 30240 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$3,880$2,328Jun 18, 2018Final
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$5,174$3,104Jun 18, 2018Final
Citation 1, item 3
29 CFR 1910.212(a)(3)(iv)(b) · Machine guarding
Serious$5,174$3,104Jun 18, 2018Final

Inspection 341607752 OPENED JUL 8, 2016Closed

Complaint · Partial · Safety · 22 employees at the site · Closed Sep 28, 2016

830 Old Hutchinson Mill Road, Lagrange, GA 30240 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$2,181$1,309Aug 23, 2016Final

Inspection 341134781 OPENED DEC 15, 2015Closed

Planned · Partial · Health · 15 employees at the site · Closed Jan 14, 2016

830 Old Hutchinson Mill Road, Lagrange, GA 30240 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(h)(2)(i)

(i) All respirators shall be stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals, and they shall be packed or stored to prevent deformation of the facepiece and exhalation valve.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.252 · Welding fire safety

Other fabricated structural metal manufacturing employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.