OSHA SearchOSHA records by employer

Z&Z Build Inc.: OSHA inspections and violations

Brooklyn, New York · Finish Carpentry Contractors · NAICS 238350

2inspections
4citation items
$14,517current penalties
Dec 12, 2024last inspection

OSHA has inspected Z&Z Build Inc. 2 times in New York since 2024.

The latest one began on Dec 12, 2024 to follow up on an earlier case, in Brooklyn.

Those inspections ended with 4 citation items: 4 serious.

Penalties were first proposed at $14,517 and still stand at $14,517.

Job-site wiring comes up most often in these citations: 3 items under 1926.405.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Z&Z Build Inc. averages $14,517 (1 cited inspection).

Z&Z Build Inc.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

362employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Z&Z Build Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347929911 OPENED DEC 12, 2024Closed

Follow-up · Partial · Safety · 4 employees at the site · Closed Mar 13, 2025

8761 26th Ave., Brooklyn, NY 11214 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347417289 OPENED APR 16, 2024Closed

Planned · Partial · Safety · 4 employees at the site · Closed May 8, 2025

8761 26th Avenue, Brooklyn, NY 11214 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(d) · Job-site wiring
Serious$4,839$4,839Oct 8, 2024Final
Citation 1, item 2
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Serious$2,765$2,765Oct 8, 2024Final
Citation 1, item 3
29 CFR 1926.405(j)(1)(i) · Job-site wiring
Serious$2,765$2,765Oct 8, 2024Final
Citation 1, item 4
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$4,148$4,148Oct 8, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(d)

(d) Switchboards and panelboards. Switchboards that have any exposed live parts shall be located in permanently dry locations and accessible only to qualified persons. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons. Exposed blades of knife switches shall be dead when open.

29 CFR 1926.405(g)(2)(iii)

(iii) Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.

29 CFR 1926.405(j)(1)(i)

(j) Equipment for general use—(1) Lighting fixtures, lampholders, lamps, and receptacles—(i) Live parts. Fixtures, lampholders, lamps, rosettes, and receptacles shall have no live parts normally exposed to employee contact. However, rosettes and cleat-type lampholders and receptacles located at least 8 feet (2.44 m) above the floor may have exposed parts.

29 CFR 1926.451 · Scaffolds, general requirements

Other finish carpentry contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.