OSHA SearchOSHA records by employer

Zacca Construction, LLC: OSHA inspections and violations

San Antonio, Texas · Water and Sewer Line and Related Structures Construction · NAICS 237110

4inspections
8citation items
$28,523current penalties
Dec 17, 2024last inspection

Since 2019, OSHA inspectors have visited Zacca Construction, LLC in Texas 4 times.

The most recent inspection opened on Dec 17, 2024 as a planned inspection, in San Antonio and is still open.

In all, OSHA issued 8 citation items: 7 serious and 1 repeat.

The proposed penalties came to $49,452; today they stand at $28,523, 42% less.

The rule cited most here is 1926.651 (excavations), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Zacca Construction, LLC averages $7,131 across 4 cited inspections.

Zacca Construction, LLC: OSHA citation items per year, 2019 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

401employers cited

12 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Zacca Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347941171 OPENED DEC 17, 2024Open

Planned · Partial · Safety · 7 employees at the site · Open

Wonderland Place & 211 Hwy, San Antonio, TX 78253 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(j)(2) · Excavations
Serious$8,276$4,000Apr 22, 2025Final
Citation 1, item 2
29 CFR 1926.652(a)(1) · Trench protection
Serious$8,276$4,000Apr 22, 2025Final
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$6,620$3,500Apr 22, 2025Final

Inspection 345449284 OPENED JUL 28, 2021Closed

Planned · Partial · Safety · 20 employees at the site · Closed Jan 13, 2022

Stolte Ranch, Unit 1b, San Antonio, TX 78245 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.651(e) · Excavations
Serious$5,461$4,000Sep 23, 2021Final
Citation 2, item 1
29 CFR 1926.651(c)(2) · Excavations
Repeat$10,922$8,000Sep 23, 2021Final

Inspection 345161343 OPENED FEB 24, 2021Closed

Planned · Partial · Safety · 45 employees at the site · Closed Oct 14, 2021

300 Block Of Horal Drive & Garden Brook Drive Cardinal Ridge Subdivision, San Antonio, TX 78245 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(c)(3)(iii) · Trench protection
Serious$4,096$2,000Jul 30, 2021Final
Citation 1, item 2
29 CFR 1926.652(g)(1)(ii) · Trench protection
Serious$4,096$2,000Jul 30, 2021Final

Inspection 343780805 OPENED FEB 12, 2019Closed

Planned · Partial · Safety · 7 employees at the site · Closed Apr 18, 2019

Rosillo Creek Subdivision Lot 40, San Antonio, TX 78220 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$1,705$1,023Mar 11, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(e)

(e) Exposure to falling loads. No employee shall be permitted underneath loads handled by lifting or digging equipment. Employees shall be required to stand away from any vehicle being loaded or unloaded to avoid being struck by any spillage or falling materials. Operators may remain in the cabs of vehicles being loaded or unloaded when the vehicles are equipped, in accordance with § 1926.601(b)(6), to provide adequate protection for the operator during loading and unloading operations.

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in Texas