Zaist Construction Management LLC: OSHA inspections and violations

Jackson, Wyoming · Commercial and Institutional Building Construction · NAICS 236220

5inspections
4citation items
$2,280current penalties
Feb 26, 2015last inspection

Since 2000, OSHA inspectors have visited Zaist Construction Management LLC in Wyoming 5 times.

The most recent inspection opened on Feb 26, 2015 as a planned inspection, in Teton Village.

In all, OSHA issued 4 citation items: 2 serious and 2 other-than-serious.

The penalties, $2,280 in total, stand where OSHA first set them.

The rule cited most here is 1926.150 (fire protection), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Zaist Construction Management LLC averages $1,530 across 1 cited inspection.

Zaist Construction Management LLC: OSHA citation items per year, 2000 to 2015
Citation items per year, by inspection date.

Wyoming · latest 90 days of OSHA records

31employers cited

Get notified the morning OSHA posts each new citation in Wyoming: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wyoming

Checking a subcontractor, a client or your own company? Watch Zaist Construction Management LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340427673 OPENED FEB 26, 2015Closed

Planned · Complete · Safety · 5 employees at the site · Closed Sep 16, 2015

3275 Village Dr., Teton Village, WY 83025 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.153(j) · Liquefied petroleum gas (LP-Gas)
Serious$1,530$1,530Apr 8, 2015Final
Citation 2, item 1
29 CFR 1926.502(b)(1) · Fall protection systems
Other-than-serious$0$0Apr 8, 2015Final

Inspection 314515768 OPENED APR 3, 2014Closed

Planned · Complete · Safety · 5 employees at the site · Closed Apr 3, 2014

655 Powderhorn Ln, Jackson, WY 83001 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307810226 OPENED MAR 23, 2005Closed

Planned · Complete · Safety · 3 employees at the site · Closed Nov 2, 2005

2645 West Hwy 22, Jackson, WY 83001 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1)(i) · Fire protection
Serious$750$750Sep 14, 2005Closed
Citation 2, item 1
29 CFR 1926.150(c)(5)(iii) · Fire protection
Other-than-serious$0$0Sep 14, 2005Closed

Inspection 307812040 OPENED SEP 22, 2004Closed

Planned · Complete · Safety · 3 employees at the site · Closed Sep 22, 2004

2645 West Hwy 22, Jackson, WY 83001 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 300712254 OPENED MAR 2, 2000Closed

Planned · Partial · Safety · 2 employees at the site · Closed Mar 2, 2000

3723 W. Michael Drive, Teton Village, WY 83205 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.153 · Liquefied petroleum gas (LP-Gas)

29 CFR 1926.153(j)

(j) Storage of LPG containers. Storage of LPG within buildings is prohibited.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.502(b)(1)

(1) Top edge height of top rails, or equivalent guardrail system members, shall be 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level. When conditions warrant, the height of the top edge may exceed the 45-inch height, provided the guardrail system meets all other criteria of this paragraph.

Other commercial and institutional building construction employers in Wyoming

Alert subscribers get notified of each newly cited employer in Wyoming the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.