Spray booths and spray rooms need fire-resistant construction, working ventilation, electrical equipment rated for the space, and regular removal of residue.
5,677citations since 2015
2,424employers cited
81%serious, willful or repeat
$150median penalty per item
OSHA has cited 29 CFR 1910.107 5,677 times since 2015, against 2,424 employers. Penalties on these items add up to $6,606,048 at their current amounts.
Citations per year
The parts of the rule cited most
1910.107(b)(9) · 700 citations
(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.
1910.107(b)(5)(i) · 633 citations
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
1910.107(g)(2) · 594 citations
(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.
1910.107(b)(5)(iv) · 397 citations
(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.
1910.107(c)(6) · 356 citations
(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.
1910.107(e)(2) · 293 citations
(2) Quantity. The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) kept in the vicinity of spraying operations shall be the minimum required for operations and should ordinarily not exceed a supply for 1 day or one shift. Bulk storage of portable containers of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) shall be in a separate, constructed building detached from other important buildings or cut off in a standard manner.
1910.107(g)(7) · 241 citations
(7) “No Smoking” signs. “No smoking” signs in large letters on contrasting color background shall be conspicuously posted at all spraying areas and paint storage rooms.
1910.107(c)(5) · 208 citations
(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections.
Industries cited most
- Manufacturing 4,357
- Other Services (except Public Administration) 624
- Retail Trade 185
- Construction 111
- Wholesale Trade 109
- Transportation and Warehousing 75
States cited most
- Tennessee 713
- Minnesota 389
- Virginia 378
- Pennsylvania 357
- Michigan 284
- North Carolina 267
- Maryland 230
- New York 222
Recently cited employers
- Tri-State Iron Works, Inc. Memphis, TN · Oct 6, 2026
- Palfinger Marine USA Inc. Portsmouth, VA · Oct 1, 2026
- Board of Washington County Commissioners Hagerstown, MD · Sep 30, 2026
- Tecmotiv Niagara Falls, NY · Sep 30, 2026
- Brooks Collision Center, L.L.C. Piney Flats, TN · Sep 30, 2026
- Flight Power Repair Group, LLC Doral, FL · Sep 30, 2026
- Christianson Systems Inc Blomkest, MN · Sep 29, 2026
- Adler Pelzer Group Salem, VA · Sep 24, 2026
- Royal Baths Manufacturing Company Clearwater, FL · Sep 24, 2026
- Powder Coating Services of Michigan LLC Brighton, MI · Sep 23, 2026
- Brian's Creative Woodwork Inc. Peotone, IL · Sep 22, 2026
- Victory Woodworks Inc. Sparks, NV · Sep 21, 2026