OSHA has cited 29 CFR 1917.50 57 times since 2015, against 39 employers. Penalties on these items add up to $465,508 at their current amounts.
Citations per year
The parts of the rule cited most
1917.50(a) · 19 citations
(a) The employer shall not use any material handling device listed in paragraph (c) of this section until he has ascertained that the device has been certificated, as evidenced by current and valid documents attesting to compliance with the requirements of paragraph (b) of this section.
1917.50(c)(1) · 19 citations
(1) Each crane and derrick shall be tested as a unit quadrennially, and shall be examined annually. Certificates of tests and examinations shall be made readily available for inspection.
1917.50(c)(2) · 6 citations
(2) Bulk cargo spouts and suckers, together with any portable extensions and rigging or outriggers supporting them vertically, shall be examined annually. Certificates attesting to the required examination shall be made readily available for inspection.
1917.50(b)(1) · 5 citations
(1) In accordance with part 1919 of this chapter, by persons then currently accredited by the Occupational Safety and Health Administration as provided in that part; or
1917.50(c)(6) · 3 citations
(6) Wire rope and loose gear obtained after October 3, 1983, and used for material handling shall have been tested and certificated before being placed into use in accordance with the provisions of paragraphs (a), (c), and (d) of §§ 1919.31 and 1919.32 through 1919.34 of this chapter as applicable. Certificates attesting to the required tests, inspections and examinations shall be available.
1917.50(c)(5)(i) · 1 citations
(5) Special gear. (i) Special stevedoring gear provided by the employer, the strength of which depends upon components other than commonly used stock items such as shackles, ropes, or chains, and that has a Safe Working Load (SWL) greater than five short tons (10,000 lbs or 4.54 metric tons) shall be inspected and tested as a unit before initial use (see Table A in paragraph (c)(5)(ii) of this section). In addition, any special stevedoring gear that suffers damage necessitating structural repair shall be inspected and retested after repair and before being returned to service.
1917.50(c)(5)(ii) · 1 citations
(ii) Special stevedoring gear provided by the employer that has a SWL of five short tons (10,000 lbs or 4.54 metric tons) or less shall be inspected and tested as a unit before initial use according to paragraphs (d) and (e) of this section or by a designated person (see Table A in this paragraph (c)(5)(ii)).
1917.50(c)(5)(iv) · 1 citations
(iv) All cargo handling gear covered by this section with a SWL greater than five short tons (10,000 lbs. or 4.54 metric tons) shall be proof load tested according to Table A of this section every 4 years in accordance with paragraph (b) of this section or by a designated person.
Industries cited most
- Transportation and Warehousing 41
- Manufacturing 15
- Wholesale Trade 1
Recently cited employers
- Viking Lumber Company, Inc. Craig, AK · May 8, 2026
- E.C. Phillips & Son, Inc Ketchikan, AK · Apr 22, 2026
- River Docks, Inc. Alsip, IL · Apr 22, 2026
- JSW Steel (USA) Inc. Baytown, TX · Dec 15, 2025
- River Docks, Inc. Alsip, IL · Nov 7, 2025
- North America Stevedoring Company, LLC Chicago, IL · Nov 7, 2025