OSHA SearchOSHA records by employer

29 CFR 1918.94: Ventilation and atmospheric conditions (See also § 1918.2, definitions of Hazardous cargo, materials, substance or atmosphere and Ro-Ro operations)

Subpart I—General Working Conditions.

3citations since 2015
3employers cited
67%serious, willful or repeat
$2,900median penalty per item

OSHA has cited 29 CFR 1918.94 3 times since 2015, against 3 employers. Penalties on these items add up to $7,588 at their current amounts.

Citations per year

The parts of the rule cited most

1918.94(a)(1) · 3 citations

(a) Ventilation with respect to carbon monoxide. (1) When internal combustion engines exhaust into a hold, intermediate deck, or any other compartment, the employer shall ensure that the atmosphere is tested as frequently as needed to prevent carbon monoxide (CO) concentrations from exceeding allowable limits. Such tests shall be made in the area in which employees are working by persons competent in the use of the test equipment and procedures. If operations are in a deep tank or refrigerated compartment, the first test shall be made within one half hour of the time the engine starts. To decide the need for further testing, the initial test in all other cargo handling areas shall be taken no later than one hour after the time the engine starts.

Industries cited most

  • Transportation and Warehousing 3

States cited most