29 CFR 1926.154: Temporary heating devices

Subpart F—Fire Protection and Prevention

17citations since 2015
16employers cited
82%serious, willful or repeat
$1,100median penalty per item

OSHA has cited 29 CFR 1926.154 17 times since 2015, against 16 employers. Penalties on these items add up to $58,397 at their current amounts.

Citations per year

The parts of the rule cited most

1926.154(a)(1) · 10 citations

(a) Ventilation. (1) Fresh air shall be supplied in sufficient quantities to maintain the health and safety of workmen. Where natural means of fresh air supply is inadequate, mechanical ventilation shall be provided.

1926.154(b)(4) · 4 citations

(4) Heaters used in the vicinity of combustible tarpaulins, canvas, or similar coverings shall be located at least 10 feet from the coverings. The coverings shall be securely fastened to prevent ignition or upsetting of the heater due to wind action on the covering or other material.

1926.154(b)(3) · 2 citations

(3) Heaters not suitable for use on wood floors shall not be set directly upon them or other combustible materials. When such heaters are used, they shall rest on suitable heat insulating material or at least 1-inch concrete, or equivalent. The insulating material shall extend beyond the heater 2 feet or more in all directions.

1926.154(a)(2) · 1 citations

(2) When heaters are used in confined spaces, special care shall be taken to provide sufficient ventilation in order to ensure proper combustion, maintain the health and safety of workmen, and limit temperature rise in the area.

Industries cited most

  • Construction 15
  • Utilities 2