OSHA has cited 29 CFR 1926.552 403 times since 2015, against 356 employers. Penalties on these items add up to $1,019,811 at their current amounts.
Citations per year
The parts of the rule cited most
1926.552(a)(1) · 271 citations
(a) General requirements. (1) The employer shall comply with the manufacturer's specifications and limitations applicable to the operation of all hoists and elevators. Where manufacturer's specifications are not available, the limitations assigned to the equipment shall be based on the determinations of a professional engineer competent in the field.
1926.552(a)(4) · 61 citations
(4) Hoisting ropes shall be installed in accordance with the wire rope manufacturers' recommendations.
1926.552(b)(1)(ii) · 9 citations
(ii) No person shall be allowed to ride on material hoists except for the purposes of inspection and maintenance.
1926.552(b)(2) · 7 citations
(2) All entrances of the hoistways shall be protected by substantial gates or bars which shall guard the full width of the landing entrance. All hoistway entrance bars and gates shall be painted with diagonal contrasting colors, such as black and yellow stripes.
1926.552(b)(8) · 7 citations
(8) All material hoists shall conform to the requirements of ANSI A10.5-1969, Safety Requirements for Material Hoists.
1926.552(b)(1)(i) · 5 citations
(b) Material hoists. (1)(i) Operating rules shall be established and posted at the operator's station of the hoist. Such rules shall include signal system and allowable line speed for various loads. Rules and notices shall be posted on the car frame or crosshead in a conspicuous location, including the statement “No Riders Allowed.”
1926.552(b)(3) · 5 citations
(3) Overhead protective covering of 2-inch planking, 3/4-inch plywood, or other solid material of equivalent strength, shall be provided on the top of every material hoist cage or platform.
1926.552(b)(5)(ii) · 5 citations
(ii) When a hoist tower is not enclosed, the hoist platform or car shall be totally enclosed (caged) on all sides for the full height between the floor and the overhead protective covering with 1/2-inch mesh of No. 14 U.S. gauge wire or equivalent. The hoist platform enclosure shall include the required gates for loading and unloading. A 6-foot high enclosure shall be provided on the unused sides of the hoist tower at ground level.
Industries cited most
- Construction 388
- Manufacturing 6
- Wholesale Trade 5
- Real Estate and Rental and Leasing 3
- Utilities 1
States cited most
- Georgia 98
- Illinois 60
- North Carolina 41
- New Hampshire 31
- New Jersey 29
- Massachusetts 23
- New York 23
- Connecticut 20
Recently cited employers
- JKN Construction Inc Concord, NH · Oct 2, 2026
- C&G General Construction Inc. Prospect Heights, IL · Oct 1, 2026
- Roberto Gomes Joliet, IL · Sep 25, 2026
- TTLC, Inc. Downers Grove, IL · Sep 18, 2026
- Jtony's Construction Corporation Farmingdale, ME · Sep 16, 2026
- Lece Construction Corp. New Lenox, IL · Sep 10, 2026
- DJL Carpentry Incorporated Binghamton, NY · Sep 4, 2026
- Force Home Improvement Inc Concord, NH · Aug 20, 2026
- Paramount Roofing LLC Concord, NH · Aug 20, 2026
- Christopher Cano Mokena, IL · Jul 30, 2026
- Pioneer Home Improvement Corporation Syracuse, NY · Jul 10, 2026
- Raptor Exteriors, Inc. Schaumburg, IL · Jul 7, 2026