OSHA SearchOSHA records by employer

1836 Installations LLC: OSHA inspections and violations

El Paso, Texas · Finish Carpentry Contractors · NAICS 238350

1inspections
4citation items
$28,000current penalties
May 2, 2025last inspection

OSHA inspectors have visited 1836 Installations LLC in Texas one time.

It opened on May 2, 2025 on a referral, in El Paso.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $56,748; today they stand at $28,000, 51% less.

The rule cited most here is 1926.1053 (ladders in construction), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. 1836 Installations LLC averages $28,000 across 1 cited inspection.

1836 Installations LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites 1836 Installations LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348225111 OPENED MAY 2, 2025Closed

Referral · Partial · Safety · 6 employees at the site · Closed Aug 1, 2025

311 S Eucalyptus, El Paso, TX 79905 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$14,187$14,000Jul 2, 2025Final
Citation 1, item 1b
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$14,187$0Jul 2, 2025Final
Citation 1, item 2a
29 CFR 1926.1053(b)(8) · Ladders in construction
Serious$14,187$14,000Jul 2, 2025Final
Citation 1, item 2b
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$14,187$0Jul 2, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

Other finish carpentry contractors employers in Texas