OSHA SearchOSHA records by employer

4 Swift Service, LLC: OSHA inspections and violations

Carrizo Springs, Texas · Support Activities for Oil and Gas Operations · NAICS 213112

2inspections
4citation items
$5,940current penalties
Jan 7, 2015last inspection

Since 2015, OSHA inspectors have visited 4 Swift Service, LLC in Texas 2 times.

The most recent inspection opened on Jan 7, 2015 on a referral, in Carrizo Springs.

In all, OSHA issued 4 citation items: 3 serious and 1 other-than-serious.

The penalties, $5,940 in total, stand where OSHA first set them.

The rule cited most here is 1910.134 (respiratory protection), 3 times.

Among mining and oil and gas employers, the typical cited inspection since 2015 ends with a $2,883 penalty. 4 Swift Service, LLC averages $5,940 across 1 cited inspection.

It reported 1 severe injury to OSHA since 2015.

4 Swift Service, LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

401employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch 4 Swift Service, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340163815 OPENED JAN 7, 2015Closed

Referral · No inspection · Safety · 5 employees at the site · Closed Jan 27, 2015

1405 Fm 1556, Carrizo Springs, TX 78834 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340169416 OPENED JAN 7, 2015Closed

Referral · Complete · Health · 7 employees at the site · Closed Mar 21, 2018

1405 Fm 1556, Carrizo Springs, TX 78834 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$2,800$2,800Feb 18, 2015Final
Citation 1, item 1b
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Feb 18, 2015Final
Citation 1, item 2
29 CFR 1910.146(c)(4) · Permit-required confined spaces
Serious$2,800$2,800Feb 18, 2015Final
Citation 2, item 1
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Other-than-serious$340$340Feb 18, 2015Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jan 6, 2015, Carrizo Springs: Hospitalization · general symptoms, unspecified · body systems

Two employees of 4 Swift Service passed out in a tank that was being cleaned. Employees proceeded into a tank which had been closed, but was opened by an employee. Employees went inside to clean, but were supposed to clean the outside of the tank only. Both employees were transported to the hospital, but only one employee was admitted.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(f)(2)

(2) Deep breathing. In a normal standing position, the subject shall breathe slowly and deeply, taking caution so as not to hyperventilate.

29 CFR 1910.134(h)(2)(i)

(i) All respirators shall be stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals, and they shall be packed or stored to prevent deformation of the facepiece and exhalation valve.

29 CFR 1910.146 · Permit-required confined spaces

Other support activities for oil and gas operations employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.