OSHA SearchOSHA records by employer

401Kable, Inc.: OSHA inspections and violations

Odessa, Texas · Machine Shops · NAICS 332710

1inspections
2citation items
$4,237current penalties
Dec 14, 2016last inspection

OSHA has inspected 401Kable, Inc. once in Texas.

The inspection began on Dec 14, 2016 as a planned inspection, in Odessa.

That inspection ended with 2 citation items: 2 serious.

Penalties were first proposed at $7,062 and now stand at $4,237, 40% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and 401Kable, Inc. averages $4,237 (1 cited inspection).

401Kable, Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites 401Kable, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341976181 OPENED DEC 14, 2016Closed

Planned · Complete · Safety · 4 employees at the site · Closed Mar 6, 2019

12001 Cr 125 West, Odessa, TX 79765 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Serious$3,803$2,282Mar 14, 2017Final
Citation 1, item 2
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$3,259$1,955Mar 14, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(7)(i)

(i) Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment.

Other machine shops employers in Texas