A-1 Body, Inc.: OSHA inspections and violations

Linthicum Heights, Maryland · Automotive Body, Paint, and Interior Repair and Maintenance · NAICS 811121

1inspections
14citation items
$689current penalties
Nov 15, 2021last inspection

A-1 Body, Inc. has one OSHA inspection on record in Maryland.

OSHA opened it on Nov 15, 2021 after a complaint, in Linthicum Heights.

From that inspection OSHA issued 14 citation items: 6 serious and 8 other-than-serious.

OSHA proposed $1,350 in penalties. After settlements and reviews the total is $689, down 49%.

Most often, OSHA cited 1910.134, respiratory protection (4 items).

For context, across all repair and personal services employers the median penalty per cited inspection since 2015 is $1,200. A-1 Body, Inc. averages $689 over 1 cited inspection in that time.

A-1 Body, Inc.: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

189employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch A-1 Body, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345640130 OPENED NOV 15, 2021Closed

Complaint · Complete · Health · 13 employees at the site · Closed Jun 1, 2022

6898 Baltimore Annapolis Blvd., Linthicum Heights, MD 21090 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$450$243Feb 17, 2022Final
Citation 1, item 1b
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$0$0Feb 17, 2022Final
Citation 1, item 1c
29 CFR 1910.107(f)(1) · Spray painting and finishing
Serious$0$0Feb 17, 2022Final
Citation 1, item 2
29 CFR 1910.151(c) · First aid and eyewash
Serious$450$203Feb 17, 2022Final
Citation 1, item 3a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$450$243Feb 17, 2022Final
Citation 1, item 3b
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0Feb 17, 2022Final
Citation 2, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Feb 17, 2022Final
Citation 2, item 2
29 CFR 1910.134(c)(3) · Respiratory protection
Other-than-serious$0$0Feb 17, 2022Final
Citation 2, item 3
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Feb 17, 2022Final
Citation 2, item 4
29 CFR 1910.134(f)(1) · Respiratory protection
Other-than-serious$0$0Feb 17, 2022Final
Citation 2, item 5
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Feb 17, 2022Final
Citation 2, item 6
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Feb 17, 2022Final
Citation 2, item 7
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Feb 17, 2022Final
Citation 2, item 8
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$0$0Feb 17, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.107(f)(1)

(f) Protection—(1) Conformance. In sprinklered buildings, the automatic sprinkler system in rooms containing spray finishing operations shall conform to the requirements of § 1910.159. In unsprinklered buildings where sprinklers are installed only to protect spraying areas, the installation shall conform to such standards insofar as they are applicable. Sprinkler heads shall be located so as to provide water distribution throughout the entire booth.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.305 · Electrical wiring methods

Other automotive body, paint, and interior repair and maintenance employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.