OSHA SearchOSHA records by employer

A & H Plumbing, Inc.: OSHA inspections and violations

Washington, District of Columbia · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

2inspections
2citation items
$3,200current penalties
Oct 18, 2023last inspection

A & H Plumbing, Inc. has 2 OSHA inspections on record in District of Columbia, the first in 2015.

OSHA's last visit started on Oct 18, 2023, in Washington.

Across those inspections OSHA issued 2 citation items: 2 serious.

OSHA proposed $5,007 in penalties. After settlements and reviews the total is $3,200, down 36%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. A & H Plumbing, Inc. averages $3,200 over 1 cited inspection in that time.

A & H Plumbing, Inc.: OSHA citation items per year, 2015 to 2023
Citation items per year, by inspection date.

District of Columbia · latest 90 days of OSHA records

13employers cited

Get notified the morning OSHA posts each new citation in District of Columbia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in District of Columbia

Checking a subcontractor, a client or your own company? Watch A & H Plumbing, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347042608 OPENED OCT 18, 2023Closed

Unprogrammed other · Complete · Safety · 15 employees at the site · Closed Apr 29, 2024

113 Potomac Ave Sw, Washington, DC 20024 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340936723 OPENED SEP 22, 2015Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed Dec 18, 2015

1380 Quincy Street, Nw, Washington, DC 20010 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,731$1,750Nov 10, 2015Final
Citation 1, item 2
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$2,276$1,450Nov 10, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.701(b)

(b) Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, shall be guarded to eliminate the hazard of impalement.

Other plumbing, heating, and air-conditioning contractors employers in District of Columbia

Alert subscribers get notified of each newly cited employer in District of Columbia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.