Inspection 342550027 OPENED AUG 15, 2017Closed
552 Decatur Street Se, Atlanta, GA 30312 · Forging and Stamping · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected A & R Ironworks 2 times in Georgia since 2016.
The latest one began on Aug 15, 2017 to follow up on an earlier case, in Atlanta.
Those inspections ended with 9 citation items: 9 serious.
Penalties were first proposed at $26,615 and now stand at $15,969, 40% lower after settlements or reviews.
Respiratory protection comes up most often in these citations: 4 items under 1910.134.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and A & R Ironworks averages $15,969 (1 cited inspection).
Georgia · latest 90 days of OSHA records
150employers cited
Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Georgia
Checking a subcontractor, a client or your own company? Watch A & R Ironworks and get notified the morning OSHA posts a new citation for it.
Watch this company552 Decatur Street Se, Atlanta, GA 30312 · Forging and Stamping · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
552 Decatur Street Se, Atlanta, GA 30312 · Forging and Stamping · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.107(b)(5)(i) · Spray painting and finishing |
Serious | $3,802 | $2,281 | Apr 17, 2017 | Final |
| Citation 1, item 2 29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing |
Serious | $3,802 | $2,281 | Apr 17, 2017 | Final |
| Citation 1, item 3 29 CFR 1910.107(b)(10) · Spray painting and finishing |
Serious | $3,802 | $2,281 | Apr 17, 2017 | Final |
| Citation 1, item 4 29 CFR 1910.107(e)(9) · Spray painting and finishing |
Serious | $3,802 | $2,281 | Apr 17, 2017 | Final |
| Citation 1, item 5a 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $3,802 | $2,281 | Apr 17, 2017 | Final |
| Citation 1, item 5b 29 CFR 1910.134(k) · Respiratory protection |
Serious | $0 | $0 | Apr 17, 2017 | Final |
| Citation 1, item 5c 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $0 | $0 | Apr 17, 2017 | Final |
| Citation 1, item 5d 29 CFR 1910.134(f)(1) · Respiratory protection |
Serious | $0 | $0 | Apr 17, 2017 | Final |
| Citation 1, item 6 29 CFR 1910.252(b)(2)(iii) · Welding fire safety |
Serious | $7,605 | $4,563 | Apr 17, 2017 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.107(b)(10)
(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.
29 CFR 1910.107(b)(5)(i)
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(b)(5)(iv)
(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.
Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.