A Plus Electrical Service LLC: OSHA inspections and violations

Norfolk, Virginia · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

3inspections
8citation items
$2,062current penalties
Aug 18, 2022last inspection

OSHA has inspected A Plus Electrical Service LLC 3 times in Virginia since 2019.

The latest one began on Aug 18, 2022 as a planned inspection, in Yorktown.

Those inspections ended with 8 citation items: 8 serious.

Penalties were first proposed at $2,945 and now stand at $2,062, 30% lower after settlements or reviews.

Fall protection systems comes up most often in these citations: 3 items under 1926.502.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and A Plus Electrical Service LLC averages $1,031 (2 cited inspections).

A Plus Electrical Service LLC: OSHA citation items per year, 2019 to 2022
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

248employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch A Plus Electrical Service LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346187081 OPENED AUG 18, 2022Closed

Planned · Partial · Safety · 4 employees at the site · Closed Mar 6, 2023

8500 George Washington Memorial Highway, Yorktown, VA 23692 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.452(w)(6)(i) · Rules for each type of scaffold
Serious$1,810$1,267Jan 9, 2023Final
Citation 1, item 1b
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$0$0Jan 9, 2023Final
Citation 1, item 1c
29 CFR 1926.502(i)(2) · Fall protection systems
Serious$0$0Jan 9, 2023Final
Citation 1, item 1d
29 CFR 1926.502(i)(3) · Fall protection systems
Serious$0$0Jan 9, 2023Final
Citation 1, item 1e
29 CFR 1926.502(i)(4) · Fall protection systems
Serious$0$0Jan 9, 2023Final

Inspection 345767495 OPENED FEB 2, 2022Closed

Planned · Partial · Safety · 20 employees at the site · Closed Jul 11, 2022

231 Lincoln Street, Hampton, VA 23669 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.403(h) · Electrical equipment on job sites
Serious$1,135$794Jun 8, 2022Final
Citation 1, item 1b
29 CFR 1926.405(a)(2)(ii)(f) · Job-site wiring
Serious$0$0Jun 8, 2022Final
Citation 1, item 1c
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$0$0Jun 8, 2022Final

Inspection 343756458 OPENED JAN 29, 2019Closed

Planned · Complete · Safety · 18 employees at the site · Closed Jan 29, 2019

2415 Ballentine Blvd., Norfolk, VA 23509 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(h)

(h) Identification of disconnecting means and circuits. Each disconnecting means required by this subpart for motors and appliances shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. These markings shall be of sufficient durability to withstand the environment involved.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(f)

(F) Temporary lights shall not be suspended by their electric cords unless cords and lights are designed for this means of suspension.

29 CFR 1926.405(b)(1)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems