OSHA SearchOSHA records by employer

A to Z Laminating Specialists Inc.: OSHA inspections and violations

Wentzville, Missouri · Institutional Furniture Manufacturing · NAICS 337127

2inspections
12citation items
$8,000current penalties
Jan 10, 2019last inspection

A to Z Laminating Specialists Inc. has 2 OSHA inspections on record in Missouri, the first in 2005.

OSHA's last visit started on Jan 10, 2019 as a planned inspection, in Wentzville.

Across those inspections OSHA issued 12 citation items: 12 serious.

OSHA proposed $14,398 in penalties. After settlements and reviews the total is $8,000, down 44%.

Most often, OSHA cited 1910.107, spray painting and finishing (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. A to Z Laminating Specialists Inc. averages $8,000 over 1 cited inspection in that time.

A to Z Laminating Specialists Inc.: OSHA citation items per year, 2005 to 2019
Citation items per year, by inspection date.

Missouri · latest 90 days of OSHA records

124employers cited

Get notified the morning OSHA posts each new citation in Missouri: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Missouri

Checking a subcontractor, a client or your own company? Watch A to Z Laminating Specialists Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343704060 OPENED JAN 10, 2019Closed

Planned · Complete · Health · 12 employees at the site · Closed Dec 19, 2019

1 Quality Ct., Wentzville, MO 63385 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Serious$3,789$2,000Mar 5, 2019Final
Citation 1, item 1b
29 CFR 1910.106(h)(8)(iii) · Flammable liquids
Serious$0$0Mar 5, 2019Final
Citation 1, item 2a
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$3,789$2,000Mar 5, 2019Final
Citation 1, item 2b
29 CFR 1910.107(c)(7) · Spray painting and finishing
Serious$0$0Mar 5, 2019Final
Citation 1, item 2c
29 CFR 1910.107(g)(1) · Spray painting and finishing
Serious$0$0Mar 5, 2019Final
Citation 1, item 2d
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$0$0Mar 5, 2019Final
Citation 1, item 3a
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$3,789$2,000Mar 5, 2019Final
Citation 1, item 3b
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$0$0Mar 5, 2019Final
Citation 1, item 3c
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0Mar 5, 2019Final
Citation 1, item 3d
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Mar 5, 2019Final
Citation 1, item 4a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$3,031$2,000Mar 5, 2019Final
Citation 1, item 4b
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Mar 5, 2019Final

Inspection 307274415 OPENED FEB 16, 2005Closed

Planned · No inspection · Safety · 15 employees at the site · Closed Mar 14, 2005

1 Quality Court, Wentzville, MO 63385 · Institutional Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(i)

(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.107(c)(7)

(7) Lamps. Electric lamps outside of, but within twenty (20) feet of any spraying area, and not separated therefrom by a partition, shall be totally enclosed to prevent the falling of hot particles and shall be protected from mechanical injury by suitable guards or by location.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

Other institutional furniture manufacturing employers in Missouri

Alert subscribers get notified of each newly cited employer in Missouri the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.