Inspection 341209534 OPENED JAN 27, 2016Closed
259 Murdock Rd, Troutman, NC 28166 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Troutman, North Carolina · Other Concrete Product Manufacturing · NAICS 327390
Since 1993, OSHA inspectors have visited Abt, Inc. in North Carolina 10 times.
The most recent inspection opened on Jan 27, 2016 to follow up on an earlier case, in Troutman.
In all, OSHA issued 67 citation items: 21 serious and 46 other-than-serious.
The proposed penalties came to $13,239; today they stand at $10,551, 20% less.
The rule cited most here is 1910.1200 (hazard communication), 16 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Abt, Inc. averages $3,750 across 1 cited inspection.
Want to know if OSHA cites Abt, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company259 Murdock Rd, Troutman, NC 28166 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
259 Murdock Rd, Troutman, NC 28166 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.138(a) · Gloves and hand protection |
Serious | $750 | $500 | Jul 17, 2015 | Closed |
| Citation 1, item 2a 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $2,500 | $1,625 | Jul 17, 2015 | Closed |
| Citation 1, item 2b 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $0 | $0 | Jul 17, 2015 | Closed |
| Citation 1, item 3 29 CFR 1910.178(m)(7) · Forklifts and other powered industrial trucks |
Serious | $2,500 | $1,625 | Jul 17, 2015 | Closed |
259 Murdock Road, Troutman, NC 28166 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.134(c)(2)(i) · Respiratory protection |
Other-than-serious | $0 | $0 | Mar 24, 2009 | Closed |
| Citation 1, item 2 29 CFR 1910.134(c)(2)(ii) · Respiratory protection |
Other-than-serious | $0 | $0 | Mar 24, 2009 | Closed |
259 Murdock Road, Troutman, NC 28166 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.106(b)(2)(viia) · Flammable liquids |
Other-than-serious | $0 | $0 | Feb 4, 2002 | Closed |
| Citation 1, item 1b 29 CFR 1910.106(b)(2)(viic)(6) · Flammable liquids |
Other-than-serious | $0 | $0 | Feb 4, 2002 | Closed |
| Citation 1, item 2a 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Feb 4, 2002 | Closed |
| Citation 1, item 2b 29 CFR 1910.132(f)(4) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Feb 4, 2002 | Closed |
| Citation 1, item 3a 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Feb 4, 2002 | Closed |
| Citation 1, item 3b 29 CFR 1910.1200(f)(5)(ii) · Hazard communication |
Other-than-serious | $0 | $0 | Feb 4, 2002 | Closed |
| Citation 1, item 3c 29 CFR 1910.1200(h)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Feb 4, 2002 | Closed |
259 Murdock Road, Troutman, NC 28166 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
259 Murdock Road, Troutman, NC 28166 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $700 | $700 | Sep 24, 2001 | Closed |
| Citation 1, item 2 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $500 | $500 | Sep 24, 2001 | Closed |
| Citation 1, item 3 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $500 | $500 | Sep 24, 2001 | Closed |
| Citation 1, item 4a 29 CFR 1910.179(n)(3)(vi) · Overhead and gantry cranes |
Serious | $500 | $500 | Sep 24, 2001 | Closed |
| Citation 1, item 4b 29 CFR 1910.179(k)(1)(i) · Overhead and gantry cranes |
Serious | $0 | $0 | Sep 24, 2001 | Closed |
| Citation 1, item 4c 29 CFR 1910.179(j)(3) · Overhead and gantry cranes |
Serious | $0 | $0 | Sep 24, 2001 | Closed |
| Citation 1, item 5 29 CFR 1910.304(f)(4) · Grounding and circuit protection |
Serious | $250 | $250 | Sep 24, 2001 | Closed |
| Citation 2, item 1 29 CFR 1910.22(d)(1) · General requirements |
Other-than-serious | $0 | $0 | Sep 24, 2001 | Closed |
| Citation 2, item 2 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Sep 24, 2001 | Closed |
| Citation 2, item 3 29 CFR 1910.157(g)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Sep 24, 2001 | Closed |
| Citation 2, item 4 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Sep 24, 2001 | Closed |
| Citation 2, item 5 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Sep 24, 2001 | Closed |
| Citation 2, item 6 29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Sep 24, 2001 | Closed |
| Citation 2, item 7 29 CFR 1910.305(j)(2)(ii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Sep 24, 2001 | Closed |
| Citation 2, item 8 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 24, 2001 | Closed |
259 Murdock Road, Troutman, NC 28166 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(6)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Sep 30, 1997 | Closed |
| Citation 1, item 2 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Sep 30, 1997 | Closed |
| Citation 1, item 3 29 CFR 1910.179(n)(2)(ii) · Overhead and gantry cranes |
Other-than-serious | $0 | $0 | Sep 30, 1997 | Closed |
| Citation 1, item 4 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Sep 30, 1997 | Closed |
| Citation 1, item 5 29 CFR 1910.334(a)(2)(ii) · Using electrical equipment |
Other-than-serious | $0 | $0 | Sep 30, 1997 | Closed |
| Citation 1, item 6 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 30, 1997 | Closed |
| Citation 1, item 7 29 CFR 1910.1200(f)(5)(ii) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 30, 1997 | Closed |
Highway 268, Roaring River, NC 28669 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 7F0101 A04 AA2 |
Other-than-serious | $688 | $0 | Nov 24, 1997 | Closed |
| Citation 1, item 1b 29 CFR 1910.134(e)(5) · Respiratory protection |
Other-than-serious | $0 | $0 | Nov 24, 1997 | Closed |
| Citation 1, item 1c 29 CFR 1910.1200(h) · Hazard communication |
Other-than-serious | $0 | $0 | Nov 24, 1997 | Closed |
| Citation 1, item 2 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $688 | $688 | Nov 24, 1997 | Closed |
| Citation 1, item 3 29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts |
Serious | $688 | $688 | Nov 24, 1997 | Closed |
| Citation 2, item 1 29 CFR 1910.95(b)(1) · Noise |
Other-than-serious | $0 | $0 | Nov 24, 1997 | Closed |
| Citation 2, item 2 29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Nov 24, 1997 | Closed |
| Citation 2, item 3a 29 CFR 1910.1200(g)(2)(iv) · Hazard communication |
Other-than-serious | $0 | $0 | Nov 24, 1997 | Closed |
| Citation 2, item 3b 29 CFR 1910.1200(g)(2)(vii) · Hazard communication |
Other-than-serious | $0 | $0 | Nov 24, 1997 | Closed |
| Citation 2, item 3c 29 CFR 1910.1200(g)(2)(ix) · Hazard communication |
Other-than-serious | $0 | $0 | Nov 24, 1997 | Closed |
| Citation 2, item 3d 29 CFR 1910.1200(g)(2)(xi) · Hazard communication |
Other-than-serious | $0 | $0 | Nov 24, 1997 | Closed |
259 Murdock Road, Troutman, NC 28166 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.38(a)(1) · Emergency action plans |
Serious | $750 | $750 | Aug 3, 1994 | Closed |
| Citation 1, item 1b 29 CFR 1910.38(b)(1) · Emergency action plans |
Serious | $0 | $0 | Aug 3, 1994 | Closed |
| Citation 1, item 2 29 CFR 1910.106(h)(7)(ib) · Flammable liquids |
Serious | $750 | $750 | Aug 3, 1994 | Closed |
| Citation 1, item 3a 29 CFR 1910.132(a) · Personal protective equipment, general requirements |
Serious | $1,250 | $1,250 | Aug 3, 1994 | Closed |
| Citation 1, item 3b 29 CFR 1910.133(a)(1) · Eye and face protection |
Serious | $0 | $0 | Aug 3, 1994 | Closed |
| Citation 1, item 3c 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $0 | $0 | Aug 3, 1994 | Closed |
| Citation 2, item 1 29 CFR 1910.110(h)(14) · Storage and handling of liquefied petroleum gases |
Other-than-serious | $0 | $0 | Aug 3, 1994 | Closed |
| Citation 2, item 2a 29 CFR 1910.134(b)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Aug 3, 1994 | Closed |
| Citation 2, item 2b 29 CFR 1910.134(b)(3) · Respiratory protection |
Other-than-serious | $0 | $0 | Aug 3, 1994 | Closed |
| Citation 2, item 2c 29 CFR 1910.134(e)(5) · Respiratory protection |
Other-than-serious | $0 | $0 | Aug 3, 1994 | Closed |
| Citation 2, item 3a 29 CFR 1910.1200(e)(2) · Hazard communication |
Other-than-serious | $0 | $0 | Aug 3, 1994 | Closed |
| Citation 2, item 3b 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Aug 3, 1994 | Closed |
| Citation 2, item 3c 29 CFR 1910.1200(f)(5)(ii) · Hazard communication |
Other-than-serious | $0 | $0 | Aug 3, 1994 | Closed |
359 Murdock Rd., Troutman, NC 28166 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $225 | $225 | Mar 8, 1993 | Closed |
| Citation 1, item 1b 29 CFR 1910.1200(h) · Hazard communication |
Serious | $0 | $0 | Mar 8, 1993 | Closed |
| Citation 2, item 1 29 CFR 1910.37(g)(2) · Exit routes |
Other-than-serious | $0 | $0 | Mar 8, 1993 | Closed |
| Citation 2, item 2 29 CFR 1910.212(b) · Machine guarding |
Other-than-serious | $0 | $0 | Mar 8, 1993 | Closed |
| Citation 2, item 3 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Mar 8, 1993 | Closed |
| Citation 2, item 4 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Mar 8, 1993 | Closed |
| Citation 2, item 5 29 CFR 1910.304(a)(2) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Mar 8, 1993 | Closed |
| Citation 2, item 6 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Mar 8, 1993 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(b)(2)(viia)
(vi) Vent piping for aboveground tanks. (a) Vent piping shall be constructed in accordance with paragraph (c) of this section.
29 CFR 1910.106(b)(2)(viic)(6)
(vi) Vent piping for aboveground tanks. (a) Vent piping shall be constructed in accordance with paragraph (c) of this section.
29 CFR 1910.110(h)(14)
(h) Liquefied petroleum gas service stations—(1) Application. This paragraph applies to storage containers, and dispensing devices, and pertinent equipment in service stations where LP-Gas is stored and is dispensed into fuel tanks of motor vehicles. See paragraph (e) of this section for requirements covering use of LP-Gas as a motor fuel. All requirements of paragraph (b) of this section apply to this paragraph unless otherwise noted.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.