OSHA SearchOSHA records by employer

AC, Inc.: OSHA inspections and violations

Huntsville, Alabama · Other Metal Container Manufacturing · NAICS 332439

2inspections
15citation items
$16,720current penalties
Dec 14, 2016last inspection

Since 2011, OSHA inspectors have visited AC, Inc. in Alabama 2 times.

The most recent inspection opened on Dec 14, 2016 on a referral, in Huntsville.

In all, OSHA issued 15 citation items: 11 serious and 4 other-than-serious.

The proposed penalties came to $24,164; today they stand at $16,720, 31% less.

The rule cited most here is 1910.107 (spray painting and finishing), 6 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. AC, Inc. averages $5,704 across 1 cited inspection.

AC, Inc. also files yearly injury logs with OSHA, summarized below.

It reported 2 severe injuries to OSHA since 2015.

AC, Inc.: OSHA citation items per year, 2011 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites AC, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341977742 OPENED DEC 14, 2016Closed

Referral · Partial · Safety · 91 employees at the site · Closed Feb 27, 2017

1085 Jordan Road, Huntsville, AL 35811 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$5,704$5,704Jan 25, 2017Final

Inspection 315761460 OPENED AUG 4, 2011Closed

Complaint · Partial · Health · 60 employees at the site · Closed Oct 23, 2013

1085 Jordan Road, Huntsville, AL 35811 · Other Metal Container Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$3,060$1,836Oct 31, 2011Closed
Citation 1, item 1b
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$0$0Oct 31, 2011Closed
Citation 1, item 1c
29 CFR 1910.107(m)(1) · Spray painting and finishing
Serious$0$0Oct 31, 2011Closed
Citation 1, item 2
29 CFR 1910.107(c)(7) · Spray painting and finishing
Serious$3,060$1,836Oct 31, 2011Closed
Citation 1, item 3a
29 CFR 1910.107(e)(9) · Spray painting and finishing
Serious$3,060$1,836Oct 31, 2011Closed
Citation 1, item 3b
29 CFR 1910.107(g)(3) · Spray painting and finishing
Serious$0$0Oct 31, 2011Closed
Citation 1, item 4a
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$3,060$1,836Oct 31, 2011Closed
Citation 1, item 4b
29 CFR 1910.133(a)(3) · Eye and face protection
Serious$0$0Oct 31, 2011Closed
Citation 1, item 5
29 CFR 1910.151(c) · First aid and eyewash
Serious$3,060$1,836Oct 31, 2011Closed
Citation 1, item 6
29 CFR 1910.242(b) · Hand and power tools
Serious$2,295$1,377Oct 31, 2011Closed
Citation 2, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Oct 31, 2011Closed
Citation 2, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$765$459Oct 31, 2011Closed
Citation 2, item 3a
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$100$0Oct 31, 2011Closed
Citation 2, item 3b
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Other-than-serious$0$0Oct 31, 2011Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Huntsville site logged 0 recordable injuries or illnesses among about 60 workers: 0.0 per 100 full-time workers, against a median of 2.4 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
AC Manufacturing
Huntsville · 2024
60 000.02.4

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Mar 4, 2019, Huntsville: Amputation · amputations · fingertip(s)

An employee was setting up a lathe. As he turned the chuck with a chuck key, his left little finger was caught between the key and the operator panel. The fingertip was amputated to the nailbed.

Dec 7, 2016, Huntsville: Hospitalization, amputation · amputations · finger(s), fingernail(s), n.e.c.

An employee was operating a press machine when his left index and middle fingers were amputated.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.107(c)(7)

(7) Lamps. Electric lamps outside of, but within twenty (20) feet of any spraying area, and not separated therefrom by a partition, shall be totally enclosed to prevent the falling of hot particles and shall be protected from mechanical injury by suitable guards or by location.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.212 · Machine guarding

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.303 · Electrical equipment, general requirements

Other other metal container manufacturing employers in Alabama