Acco Engineered Systems, Inc.: OSHA inspections and violations
Commerce, California · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220
42inspections
43citation items
$139,130current penalties
Jan 16, 2026last inspection
Since 2003, OSHA inspectors have visited Acco Engineered Systems, Inc. in California 42 times.
The most recent inspection opened on Jan 16, 2026 after an accident, in San Leandro and is still open.
In all, OSHA issued 43 citation items: 7 serious and 36 other-than-serious.
The proposed penalties came to $237,820; today they stand at $139,130, 41% less.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Acco Engineered Systems, Inc. averages $10,517 across 12 cited inspections.
1 inspection on this page followed a fatal incident.
The Wage and Hour Division has 1 case on it since 2015, with $33,712 in back wages owed to workers.
Citation items per year, by inspection date.
California · latest 90 days of OSHA records
1,117employers cited
17 of them in the same industry
Get notified the morning OSHA posts each new citation in California: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Acco Engineered Systems, Inc. and get notified the morning OSHA posts a new citation for it.
OSHA records show Acco Engineered Systems, Inc. at 32 sites in 2 states. Together they've had 53 inspections and $151,397 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 32 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
Accident · Partial · Safety · 7,000 employees at the site · Open
131 S. Rodeo Drive Suite 100 (berkshire Hathaway Home Services California Properties), Beverly Hills, CA 90212 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 3276(D)(1)(A)
Other-than-serious
$560
$560
Feb 23, 2026
Open
Citation 1, item 2
29 CFR 3276(E)(15)(A)
Other-than-serious
$560
$560
Feb 23, 2026
Open
Inspection 348445016 OPENED AUG 18, 2025Open
Accident · Partial · Safety · 1 employee at the site · Open
Incident on Jul 29, 2020: Employee's fingers are amputated by falling debris
At approximately 10:15 a.m. on July 29, 2020, an employee was assisting in the instillation of 72 ft of 3-in stainless steel riser pipes on the 8th floor of a newly constructed residential high-rise construction site in excess of 60 stories. While brushing away construction debris that had gathered on the pipe surface, the suspended load dropped suddenly pinning the employee's hand between the two sections of pipe. The cause of the sudden drop of the load could not be conclusively determined. The employee sustained crushing injuries to his fingers that resulted in the surgical amputation of 1 or more fingers. He was treated and hospitalized at Long Beach Medical Center. At 10:37 a.m. on September 22, 2020, DOSH was notified from a complaint from a member of the public, the employer did not meet the reporting requirement. At approximately 12:03 p.m. on October 15, 2020, DOSH arrived on-site and issued serious accident related citations for T8CCR �1511(b). The employer failed to effectively survey the conditions associated with having an employee working in a position whereby his hands are underneath a suspended load of approximately 72 ft of 3-in stainless steel riser pipe weighing up to 1,000 lbs., and to determine the kind of safeguards necessary to execute the work in a safe manner.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 342(A)
Other-than-serious
$5,000
$5,000
Jun 9, 2021
Contested
Citation 1, item 2
29 CFR 1509(A)
Other-than-serious
$635
$635
Jun 9, 2021
Contested
Citation 1, item 3
29 CFR 3380(F)(2)
Other-than-serious
$635
$635
Jun 9, 2021
Contested
Citation 2, item 1
29 CFR 1511(B)
Serious
$18,000
$18,000
Jun 9, 2021
Contested
Inspection 344934682 OPENED SEP 15, 2020Closed
Planned · Partial · Safety · 4,000 employees at the site · Closed Oct 22, 2020
Incident on Jul 15, 2020: Employee falls through an opening during measurement and fra
At 8:00 a.m. on July 15, 2020, Employee #1, employed at a temporary construction site for a 3-story building, was taking measurements of a 12-foot by 6-foot opening for an HVAC system on the 2nd floor. While working with a coworker, Employee #1 moved the cover over the opening to obtain accurate measurements. After completing the measurements, Employee #1 stepped on the cover, which was not a single piece and broke at the joint, causing him to fall 16 feet to the first level below. Employee #1 sustained fractures to the ribs and elbows and was transported to Riverside Community Hospital, where he was hospitalized for 10 days. The incident was reported to the San Bernardino District Office on the same day. A serious accident-related violation was cited for T8CCR 1632(b)(3) regarding the cover on the opening.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 2, item 1
29 CFR 1632(B)(3)
Other-than-serious
$18,000
$600
Dec 22, 2020
Final
Inspection 344861182 OPENED JUL 29, 2020Open
Accident · Partial · Safety · 1,120 employees at the site · Open
Incident on May 26, 2020: Employee falls from ladder, fractures ankle
At approximately 7:40 P.M. on May 26, 2020, an employee, working for a building contractor, was completing construction at a commercial building using a ladder. The employee was climbing the ladder, slipped, and fell approximately 16 feet to the ground. The employee was hospitalized and treated for a fractured left ankle.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 3395(I)
Other-than-serious
$850
$0
Nov 24, 2020
Final
Inspection 344294749 OPENED SEP 9, 2019Closed
Accident · Partial · Health · 5 employees at the site · Closed Nov 15, 2019
Incident on Sep 3, 2019: Employee working outdoors is treated for heat-related illnes
At 2:30 p.m. on September 3, 2019, Employee #1 had been using a forklift to unload vehicles and move equipment and materials around the employer's fabrication yard. He also had assisted in pipefitting activities. He was finishing the work day and, not feeling well, went to rest in his personal car before leaving the worksite. The employee felt dizzy and nauseous, and he temporarily lost consciousness. He was transported to the hospital, where he was treated for heat-related illness and dehydration and then released.
No citations from this inspection.
Inspection 344056676 OPENED JUN 5, 2019Closed
Accident · Partial · Safety · 4,000 employees at the site · Closed Nov 14, 2022
Incident on May 30, 2019: Employee falls from ladder and receives shoulder dislocation
At 10:00 a.m. on May 30, 2019, an employee placed a ladder against the exterior wall of a building to access the roof to perform HVAC maintenance. As the employee climbed the ladder, the ladder's feet slipped out and the employee fell. The employee was hospitalized to treat a right shoulder dislocation and fractures to both ankles.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 2, item 1
29 CFR 3276(E)(15)(B)
Other-than-serious
$7,650
$600
Nov 19, 2019
Final
Citation 3, item 1
29 CFR 3276(E)(9)
Other-than-serious
$18,000
$5,000
Nov 19, 2019
Final
Inspection 343472437 OPENED SEP 14, 2018Closed
Complaint · Partial · Safety · 200 employees at the site · Closed Dec 18, 2018
Incident on Apr 21, 2017: Employee is struck by falling compressor and fractures ankle
At 8:40 a.m. on April 21, 2017, an employee and two coworkers were pushing a Spanco 1 ton gantry crane and York suspended compressor on the I-beam over the wall shifting the weight on the gantry crane causing the leg to buckle. The employee, who was on the other side of the wall, was struck by the crane and compressor and he fell with the compressor landing on his right leg. The employee suffered a right fibula fracture and left shoulder injury. The employee was hospitalized as well.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 3203(A)
Other-than-serious
$560
$0
Sep 29, 2017
Final
Inspection 341954147 OPENED NOV 30, 2016Closed
Accident · Partial · Safety · 8 employees at the site · Closed Mar 22, 2019
Incident on Jul 1, 2015 (fatal): Employee falls through skylight and is killed
At 12:20 p.m. on July 1, 2015, an employee was working on a General Electric exhaust fan located on a roof. The employee fell through a skylight, dropped approximately 19 feet, and struck the concrete floor, killing him.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 3203(A)(6)
Other-than-serious
$6,075
$0
Dec 9, 2015
Final
Citation 2, item 1
29 CFR 3212(E)
Serious
$18,000
$18,000
Dec 9, 2015
Final
Inspection 340094416 OPENED NOV 19, 2014Closed
Accident · Partial · Safety · 200 employees at the site · Closed Mar 25, 2016
Planned · Partial · Safety · 2 employees at the site · Closed Dec 4, 2014
Medical Dental Clinic, San Diego Naval Base Build. 3230 On Paunak St., San Diego, CA 92134 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 126202381 OPENED NOV 21, 2013Closed
Accident · Partial · Safety · 2,500 employees at the site · Closed Nov 14, 2015
Planned · Complete · Safety · 20 employees at the site · Closed Jul 24, 2014
6446 E. Washington Blvd., Commerce, CA 90040 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Aug 21, 2012: Worker fractures ribs and leg in fall from ladder
At approximately 3:00 p.m. on August 21, 2012, an employee was working for ACCO Engineered Systems, Inc., an appliance repair and maintenance firm. The incident occurred in the business administration building of a university. ACCO Engineer ed Systems installed and serviced industrial ventilation systems. According to t he employee, he had finished working on an air conditioning unit located on the roof of the building and was coming down by way of a fixed ladder. As he was clo sing the roof hatch with his right hand, he lost his grip on the ladder with his left hand. According to the employer's accident investigation report, the emplo yee fell about 15 feet (4.6 meters) onto a concrete floor. The employee landed o n his right side. He was working alone, and there were no witnesses. He managed to call emergency medical service using his cellphone. He was taken by paramedic s to a trauma hospital. He sustained fractured ribs and a broken tibia and fibul a. At approximately 5:22 p.m. that same day, the employer representative of ACCO Engineered Systems reported the incident.
No citations from this inspection.
Inspection 316517382 OPENED AUG 15, 2012Closed
Unprogrammed other · Partial · Safety · 101 employees at the site · Closed Sep 10, 2012
Accident · Partial · Safety · 300 employees at the site · Closed Sep 19, 2013
1111 Aladdin St, San Leandro, CA 94577 · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance · OSHA's record · Phone and website on Google Maps
Incident on Jul 12, 2011: Employee's hand is burnt by weld spark
At approximately 1:20 p.m. on July 12, 2011, Employee #1, of Acco Engineered Sys tems, Incorporated, was tasked to pin weld the inside insulation of the metal du ct and wipe the surface with a propanol solution for shipment. Employee #1 notic ed that one pin weld of the duct failed. He decided to replace the defective pin . When he drove a new weld, the sparks from the weld ignited the residue of the propanol on his glove. His right hand caught on fire and resulted in second degr ee burns. Employee #1 was transported to Eden Valley Hospital, Castro Valley, CA , where he was treated for his injury.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 5416 C
Other-than-serious
$800
$490
Oct 19, 2011
Final
Inspection 119917086 OPENED APR 23, 2010Closed
Planned · Partial · Safety · 60 employees at the site · Closed Apr 9, 2012
Incident on Oct 2, 2009: Employee is injured in fall from scissor lift
At approximately 11:00 a.m. on October 2, 2009, Employee #1, a metal worker who had been on the job for three months, was working from a scissor lift using a Vi ctor Model Number 100 FC oxygen-acetylene cutting torch to remove the roll-up do or brackets from a building. These brackets were located on the sides of the doo r opening and extended to the ceiling of the building at a height of 17.6 feet. Employee #1 was not familiar with the scissor lift and asked the superintendent how to operate it. After working from the scissor lift for a few minutes, he saw flames coming from the hose of the acetylene tank that was located on the groun d. He called out for someone to shut off the gas, and when no one came, he attem pted to lower the scissor lift. He used the control stick for backward and forwa rd movement, but he had forgotten that there was a separate control for raising and lowering the lift. After the unsuccessful attempt, Employee #1 climbed down the scissor lift. He slipped and fell to the concrete floor below, fracturing hi s spinal column. He was hospitalized for treatment.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 1509 A
Other-than-serious
$420
$0
Feb 8, 2010
Final
Citation 1, item 2
29 CFR 1742 D
Other-than-serious
$750
$750
Feb 8, 2010
Final
Citation 1, item 3
29 CFR 3646 L
Other-than-serious
$750
$0
Feb 8, 2010
Final
Inspection 125878371 OPENED JUL 15, 2009Closed
Planned · Complete · Safety · 1,600 employees at the site · Closed Aug 19, 2009
Accident · Partial · Safety · 150 employees at the site · Closed Jan 4, 2010
10671 Lanark St., Sun Valley, CA 91352 · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance · OSHA's record · Phone and website on Google Maps
Incident on Apr 30, 2009: Employee falls from ladder and sustains multiple fractures
At approximately 1:05 p.m. on April 3, 2009, Employee #1, a Service Technician f or a HVAC company, was servicing an HVAC unit. The HVAC unit was located on the flat roof of an approximately 20 ft warehouse, storage building. Employee #1 was going up the affixed ladder and was approximately 15 ft high, when he lost his balance and fell. He sustained multiple unspecified body fractures. Employee #1 was taken to Providence Holy Cross in Mission Hills, California, where he was ho spitalized. The investigation concluded that accident was caused as a result of the affixed ladder not being outfitted with a cage or well.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 3276 A01
Other-than-serious
$420
$420
Oct 23, 2009
Closed
Citation 2, item 1
29 CFR 3277 G02
Other-than-serious
$18,000
$750
Oct 23, 2009
Closed
Inspection 312572530 OPENED JAN 12, 2009Closed
Accident · Partial · Safety · 2,100 employees at the site · Closed Mar 3, 2009
25084 S Schulte Road, Tracy, CA 95376 · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance · OSHA's record · Phone and website on Google Maps
Incident on Oct 23, 2008: Employee's eye is injured by flying object
On October 23, 2008, Employee #1, a service technician, was hoisting a 35-lb can ister with a rope and brass-coated snap-hook. When the snap-hook failed in its n eck area, the rope and a portion of the snap-hook recoiled and struck his right eye. Employee #1 was hospitalized for treatment, including surgical removal of t he damaged eye.
No citations from this inspection.
Inspection 126197821 OPENED MAR 1, 2008Closed
Unprogrammed related · Partial · Safety · 20 employees at the site · Closed Jun 4, 2008
Incident on Jan 18, 2007: Employee is scalded by hot water
At approximately 6:30 a.m. on January 18, 2007, Employee #1 was installing a reh eat coil for the interior zones of the hotel's spa area. The HVAC unit is locate d above the 2-ft by 2-ft ceiling access panel in the hallway of the spa. While E mployee #1 was performing his work from an 8-ft A-frame ladder, a fitting for th e adjacent hot water pipe separated and sprayed hot water on him. Employees in t he area responded to Employee #1's call for help and turned off the valve for th e hot water pipe. Employee #1 sustained second-degree and third-degree burns on his left arm, left side of his chest and stomach, and his left leg, and was hosp italized for two weeks and two days.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 1509 A
Other-than-serious
$325
$325
Mar 2, 2007
Closed
Inspection 126110410 OPENED SEP 13, 2004Closed
Accident · Partial · Safety · 3 employees at the site · Closed Oct 19, 2004
Incident on Aug 24, 2004: Employee is injured in fall from ladder
At approximately 8:00 p.m. on August 24, 2004, Employee #1, a sheet metal worker with Acco Engineered Systems, was removing duct connections. While standing on the fourth rung of a fiberglass A-Frame ladder cutting duct hanger straps, he lo st his balance and the ladder slipped out from underneath him. He landed awkward ly on his left foot, which resulted in a fracture of his left fibula. Employee # 1 was hospitalized at St. Johns Hospital in Santa Monica.
No citations from this inspection.
Inspection 300782687 OPENED AUG 13, 2003Closed
Accident · Partial · Safety · 48 employees at the site · Closed Oct 7, 2006
3421 Malt Ave, Commerce, CA 90040 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Jul 29, 2003: Employee lacerates forearm when metal sheet slips and falls
At approximately 12:35 p.m. on July 29, 2003, Employee #1 was removing stainless steel sheets, 22 gauge, and 4-ft by 10-ft. They were on a storage rack approxim ately 77 inches high and he was placing them on a rolling cart approximately 33 inches high. He was not wearing any cut-resistant clothing or protective gear. W hile trying to remove a metal sheet, it became stuck on another sheet due to an oxide coating used to prevent them from sliding freely. He jerked or fanned the metal sheet, in order to trap some air in between the top and the lower sheet to break the seal. He then whipped the sheet and started to pull it out of the rac k. He was pulling and supporting one end with his left hand and pulling the shee t with the right hand. Approximately midway of pulling the sheet out, it became stuck again causing him to lose his grip on his left hand. The sheet then fell d own and slid off the rack striking him on his left forearm, causing a deep lacer ation. Employee #1 was hospitalized.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 2, item 1
29 CFR 3384 A
Other-than-serious
$25,000
$1,125
Nov 24, 2003
Final
Wage and hour cases
Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.
Period reviewed
Violations
Workers owed
Back wages
Penalties
May 23, 2021 to May 22, 2023
SAN DIEGO
44
42
$33,712
$0
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.178 · Forklifts and other powered industrial trucks
Alert subscribers get notified of each newly cited employer in California the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.