OSHA SearchOSHA records by employer

Accu-Crete, Inc.: OSHA inspections and violations

Gaithersburg, Maryland · All Other Specialty Trade Contractors · NAICS 238990

7inspections
23citation items
$8,970current penalties
Mar 23, 2017last inspection

Since 1990, OSHA inspectors have visited Accu-Crete, Inc. in Maryland 7 times.

The most recent inspection opened on Mar 23, 2017 as a planned inspection, in Rockville.

In all, OSHA issued 23 citation items: 10 serious, 1 repeat and 12 other-than-serious.

The proposed penalties came to $14,127; today they stand at $8,970, 37% less.

The rule cited most here is 1926.405 (job-site wiring), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Accu-Crete, Inc. averages $3,570 across 1 cited inspection.

Accu-Crete, Inc.: OSHA citation items per year, 1990 to 2017
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

187employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Accu-Crete, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342194719 OPENED MAR 23, 2017Closed

Planned · Complete · Safety · 3 employees at the site · Closed Aug 14, 2017

255 North Washington Street, Rockville, MD 20850 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.51(f)(1) · Sanitation
Serious$2,100$1,070Jun 27, 2017Final
Citation 1, item 2
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$2,100$1,250Jun 27, 2017Final
Citation 1, item 3
29 CFR 1926.501(b)(15) · Fall protection in construction
Serious$2,100$1,250Jun 27, 2017Final
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Jun 27, 2017Final

Inspection 316484146 OPENED MAR 20, 2012Open

Planned · Complete · Safety · 8 employees at the site · Open

370 East Diamond Avenue, Gaithersburg, MD 20877 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.350(a)(10) · Gas welding and cutting
Other-than-serious$750$750May 9, 2012Open
Citation 2, item 1
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Repeat$500$500May 9, 2012Open
Citation 3, item 1
29 CFR 1926.152(e)(4) · Flammable liquids
Other-than-serious$0$0May 9, 2012Open
Citation 3, item 2
29 CFR 1926.403(i)(1)(ii) · Electrical equipment on job sites
Other-than-serious$0$0May 9, 2012Open
Citation 3, item 3
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Other-than-serious$0$0May 9, 2012Open

Inspection 315911180 OPENED OCT 7, 2011Closed

Referral · Partial · Safety · 10 employees at the site · Closed Nov 29, 2012

370 East Diamond Avenue, Gaithersburg, MD 20877 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$3,000$2,500Dec 5, 2011Final

Inspection 315911982 OPENED SEP 16, 2011Closed

Unprogrammed other · Complete · Safety · 10 employees at the site · Closed Nov 17, 2011

370 East Diamond Avenue, Gaithersburg, MD 20877 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Oct 3, 2011Closed
Citation 1, item 2
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Oct 3, 2011Closed
Citation 1, item 3
29 CFR 50406 A01
Other-than-serious$0$0Oct 3, 2011Closed
Citation 1, item 4
29 CFR 50408 A01
Other-than-serious$0$0Oct 3, 2011Closed
Citation 1, item 5
29 CFR 50503 A
Other-than-serious$0$0Oct 3, 2011Closed

Inspection 302481759 OPENED FEB 9, 1999Closed

Planned · Complete · Safety · 19 employees at the site · Closed May 10, 1999

16699 Governor's Bridge Road, Bowie, MD 20716 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$562$250Mar 29, 1999Closed
Citation 2, item 1
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$1,350$650Mar 29, 1999Closed

Inspection 127372555 OPENED MAR 5, 1996Closed

Planned · Complete · Safety · 9 employees at the site · Closed May 20, 1996

21100 Ridge Road, Germantown, MD 20876 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Other-than-serious$0$0Apr 15, 1996Closed

Inspection 104415658 OPENED AUG 8, 1990Closed

Planned · Complete · Safety · 20 employees at the site · Closed Oct 15, 1990

719 Bestgate Road, Annapolis, MD 21401 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$555$250Sep 7, 1990Closed
Citation 2, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$555$250Sep 7, 1990Closed
Citation 3, item 1a
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$555$250Sep 7, 1990Closed
Citation 3, item 1b
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0Sep 7, 1990Closed
Citation 4, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Other-than-serious$0$0Sep 7, 1990Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.152(e)(4)

(4) The dispensing units shall be protected against collision damage.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(1)

(b) Accident prevention responsibilities. (1) It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.350 · Gas welding and cutting

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.51 · Sanitation

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

29 CFR 1926.95 · Criteria for personal protective equipment

Other all other specialty trade contractors employers in Maryland