OSHA SearchOSHA records by employer

Accurate Auto Body, Inc.: OSHA inspections and violations

Aurora, Colorado · General Automotive Repair · NAICS 811111

2inspections
13citation items
$2,720current penalties
Jun 10, 2015last inspection

OSHA has inspected Accurate Auto Body, Inc. 2 times in Colorado since 2015.

The latest one began on Jun 10, 2015 on a referral, in Aurora.

Those inspections ended with 13 citation items: 9 serious and 4 other-than-serious.

Penalties were first proposed at $5,440 and now stand at $2,720, 50% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 4 items under 1910.134.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Accurate Auto Body, Inc. averages $1,360 (2 cited inspections).

Accurate Auto Body, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

138employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Accurate Auto Body, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340693423 OPENED JUN 10, 2015Closed

Referral · Partial · Health · 20 employees at the site · Closed Sep 3, 2015

10320 E 6th Ave., Aurora, CO 80010 · General Automotive Repair · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$1,020$510Jun 24, 2015Final
Citation 1, item 1b
29 CFR 1910.106(e)(7)(i)(a) · Flammable liquids
Serious$0$0Jun 24, 2015Final
Citation 1, item 1c
29 CFR 1910.106(e)(9)(iii) · Flammable liquids
Serious$0$0Jun 24, 2015Final
Citation 1, item 2a
29 CFR 1910.134(d)(3)(iii)(b)(2) · Respiratory protection
Serious$1,020$510Jun 24, 2015Final
Citation 1, item 2b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Jun 24, 2015Final
Citation 1, item 2c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Jun 24, 2015Final
Citation 1, item 2d
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Serious$0$0Jun 24, 2015Final
Citation 2, item 1
29 CFR 1910.107(g)(3) · Spray painting and finishing
Other-than-serious$0$0Jun 24, 2015Final

Inspection 340653765 OPENED MAY 15, 2015Closed

Planned · Complete · Safety · 17 employees at the site · Closed Aug 17, 2015

10320 E 6th Ave., Aurora, CO 80010 · General Automotive Repair · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Serious$2,040$1,020Jun 24, 2015Final
Citation 1, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$1,360$680Jun 24, 2015Final
Citation 2, item 2
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Jun 24, 2015Final
Citation 2, item 3
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Jun 24, 2015Final
Citation 2, item 4
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Other-than-serious$0$0Jun 24, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.106(e)(6)(i)

(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.

29 CFR 1910.106(e)(7)(i)(a)

(7) Electrical—(i) Equipment. (a) All electrical wiring and equipment shall be installed according to the requirements of subpart S of this part.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.334 · Using electrical equipment

Other general automotive repair employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.