Ace Case Manufacturing, LLC: OSHA inspections and violations

Steelville, Missouri · Sporting and Athletic Goods Manufacturing · NAICS 339920

1inspections
6citation items
$3,606current penalties
Jan 18, 2019last inspection

OSHA has inspected Ace Case Manufacturing, LLC once in Missouri.

The inspection began on Jan 18, 2019 as a planned inspection, in Steelville.

That inspection ended with 6 citation items: 6 serious.

Penalties were first proposed at $5,152 and now stand at $3,606, 30% lower after settlements or reviews.

Spray painting and finishing comes up most often in these citations: 2 items under 1910.107.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Ace Case Manufacturing, LLC averages $3,606 (1 cited inspection).

Ace Case Manufacturing, LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Missouri · latest 90 days of OSHA records

121employers cited

Get notified the morning OSHA posts each new citation in Missouri: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Missouri

Checking a subcontractor, a client or your own company? Watch Ace Case Manufacturing, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343728838 OPENED JAN 18, 2019Closed

Planned · Complete · Health · 18 employees at the site · Closed Aug 16, 2019

490 Long Springs Rd., Steelville, MO 65565 · Sporting and Athletic Goods Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Serious$3,220$2,254Feb 12, 2019Final
Citation 1, item 1b
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$0$0Feb 12, 2019Final
Citation 1, item 1c
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0Feb 12, 2019Final
Citation 1, item 1d
29 CFR 1910.107(c)(7) · Spray painting and finishing
Serious$0$0Feb 12, 2019Final
Citation 1, item 2a
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$1,932$1,352Feb 12, 2019Final
Citation 1, item 2b
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Serious$0$0Feb 12, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(i)

(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.334 · Using electrical equipment