OSHA SearchOSHA records by employer

Adf Cable Construction Inc.: OSHA inspections and violations

Shermans Dale, Pennsylvania · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

2inspections
7citation items
$15,490current penalties
Dec 16, 2020last inspection

OSHA has inspected Adf Cable Construction Inc. 2 times in Pennsylvania since 2008.

The latest one began on Dec 16, 2020 on a referral, in Hershey.

Those inspections ended with 7 citation items: 5 serious and 2 other-than-serious.

Penalties were first proposed at $29,371 and now stand at $15,490, 47% lower after settlements or reviews.

Electrical safety in construction comes up most often in these citations: 2 items under 1926.416.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Adf Cable Construction Inc. averages $15,000 (1 cited inspection).

Adf Cable Construction Inc.: OSHA citation items per year, 2008 to 2020
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

300employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Adf Cable Construction Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345068068 OPENED DEC 16, 2020Closed

Referral · Partial · Safety · 9 employees at the site · Closed Jun 10, 2021

Sand Hill Road And Forest Avenue, Hershey, PA 17033 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Dec 11, 2020: Employee suffers electric shock, burns, and cardiac arrest w

At 1:51 p.m. on December 12, 2020, Employee #1 was standing on the ground at the rear passenger side of an Altec A40P Aerial Cable Placer Bucket Truck (Truck 55), which was being used to wind up a fiber optic cable being salvaged from metal utility poles. The employee operated the reeler control lever to wind the first of seven fiber optic cables, each approximately 4,567 feet long. The fiber optic cable, which had a metallic foil armor coating, came loose from a temporary loop and flipped up, contacting an exposed energized 69kV power conductor. The electrical current traveled 1,571 feet through the cable and into Truck 55, grounding through the vehicle's tires. The current entered the employee's right hand and arm, exited through the right foot, causing cardiac arrest and electrical burns to the right hand, right arm, stomach, and right foot. The employee was transported to the hospital for admission and treatment.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$9,557$5,000May 5, 2021Final
Citation 1, item 2
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$9,557$5,000May 5, 2021Final
Citation 1, item 3a
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$9,557$5,000May 5, 2021Final
Citation 1, item 3b
29 CFR 1926.416(a)(3) · Electrical safety in construction
Serious$0$0May 19, 2021Final
Citation 2, item 1
29 CFR 1904.4(a) · Recording criteria
Other-than-serious$0$0May 5, 2021Final
Citation 2, item 2
29 CFR 1904.39(a)(2) · Reporting deaths and severe injuries
Other-than-serious$0$0May 5, 2021Final

Inspection 116209040 OPENED APR 2, 2008Closed

Referral · Complete · Safety · 35 employees at the site · Closed Apr 21, 2008

Pisgah State Road, Shermans Dale, PA 17090 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$700$490Apr 15, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.39 · Reporting deaths and severe injuries

29 CFR 1904.39(a)(2)

(2) Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA.

29 CFR 1904.4 · Recording criteria

29 CFR 1904.4(a)

(a) Basic requirement. Each employer required by this part to keep records of fatalities, injuries, and illnesses must record each fatality, injury and illness that:

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.95 · Criteria for personal protective equipment

Other electrical contractors and other wiring installation contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.