OSHA SearchOSHA records by employer

Advance Diversified Steel Services: OSHA inspections and violations

Frisco, Texas · Ornamental and Architectural Metal Work Manufacturing · NAICS 332323

2inspections
5citation items
$15,137current penalties
Mar 25, 2025last inspection

Since 2018, OSHA inspectors have visited Advance Diversified Steel Services in Texas 2 times.

The most recent inspection opened on Mar 25, 2025 as a planned inspection, in Benbrook.

In all, OSHA issued 5 citation items: 2 serious and 3 other-than-serious.

The proposed penalties came to $25,229; today they stand at $15,137, 40% less.

The rule cited most here is 1926.753 (hoisting and rigging), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Advance Diversified Steel Services averages $7,569 across 2 cited inspections.

Advance Diversified Steel Services: OSHA citation items per year, 2018 to 2025
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Advance Diversified Steel Services and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348134958 OPENED MAR 25, 2025Closed

Planned · Complete · Safety · 38 employees at the site · Closed Jun 16, 2025

7461 W. Vickery Blvd, Benbrook, TX 76116 · Ornamental and Architectural Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Serious$4,220$2,532Apr 11, 2025Final
Citation 2, item 1
29 CFR 1904.41(a)(1)(i) · Electronic submission of Employer Identification Number (EIN) and injury and illness records to OSHA
Other-than-serious$1,655$993Apr 11, 2025Final
Citation 2, item 2
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$790$474Apr 11, 2025Final

Inspection 343669339 OPENED DEC 18, 2018Closed

Referral · Partial · Safety · 35 employees at the site · Closed Oct 4, 2019

4455 Frisco Green Ave., Frisco, TX 75034 · Ornamental and Architectural Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Dec 17, 2018: Employee is struck by falling staircase landing and fracture

At 8:25 a.m. on December 17, 2019, an employee was working as a flagger and was directing the placement for a metal stair landing. The employee was struck at the hip area and was knocked down the metal stairs when the material straps were not choked and the landing fell. The employee sustained bilateral hip fractures and was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.753(c)(2) · Hoisting and rigging
Other-than-serious$9,282$5,569Feb 15, 2019Final
Citation 1, item 2
29 CFR 1926.753(d)(2)(i) · Hoisting and rigging
Serious$9,282$5,569Feb 15, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.41 · Electronic submission of Employer Identification Number (EIN) and injury and illness records to OSHA

29 CFR 1904.41(a)(1)(i)

(a) Basic requirements—(1) Annual electronic submission of information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses. (i) If your establishment had 20-249 employees at any time during the previous calendar year, and your establishment is classified in an industry listed in appendix A to subpart E of this part, then you must electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee. You must submit the information once a year, no later than the date listed in paragraph (c) of this section of the year after the calendar year covered by the form.

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.253(b)(2)(iv)

(iv) Valve protection caps, where cylinder is designed to accept a cap, shall always be in place, hand-tight, except when cylinders are in use or connected for use.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(g)(2)(iii)

(iii) Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1926.753 · Hoisting and rigging

Other ornamental and architectural metal work manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.