OSHA SearchOSHA records by employer

Advanced Cylinder & Tank, L.L.C.: OSHA inspections and violations

Luverne, Alabama · Fuel Dealers · NAICS 454312

2inspections
4citation items
$9,400current penalties
Oct 25, 2017last inspection

OSHA has inspected Advanced Cylinder & Tank, L.L.C. 2 times in Alabama since 2015.

The latest one began on Oct 25, 2017 to follow up on an earlier case, in Luverne.

Those inspections ended with 4 citation items: 4 serious.

Penalties were first proposed at $14,300 and now stand at $9,400, 34% lower after settlements or reviews.

Working near live electrical parts comes up most often in these citations: 2 items under 1910.333.

How that compares: the median penalty per cited inspection for retail employers since 2015 is $2,140, and Advanced Cylinder & Tank, L.L.C. averages $9,400 (1 cited inspection).

1 inspection on this page followed a fatal incident.

Advanced Cylinder & Tank, L.L.C.: OSHA citation items per year, 2015 to 2017
Citation items per year, by inspection date.

Alabama · latest 90 days of OSHA records

95employers cited

Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alabama

Checking a subcontractor, a client or your own company? Watch Advanced Cylinder & Tank, L.L.C. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342727013 OPENED OCT 25, 2017Closed

Follow-up · Partial · Safety · 14 employees at the site · Closed Nov 14, 2017

145 Ferrene Dirt Road, Luverne, AL 36049 · Fuel Dealers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341093896 OPENED NOV 20, 2015Closed

Fatality or catastrophe · Partial · Safety · 14 employees at the site · Closed Apr 28, 2016

145 Ferrene Dirt Road, Luverne, AL 36049 · Fuel Dealers · OSHA's record · Phone and website on Google Maps

Incident on Nov 20, 2015 (fatal): Employee contacts power line with a crane and is killed

At 8:30 a.m. on November 20, 2015, an employee was working with a coworker picking up and hauling off propane tanks (e.g. 100 gallon). They used cranes mounted on truck tractors to load the tanks on to flat bed trailers. The tanks were positioned along the South and East perimeters of the site. There were overhead powerlines along the East perimeter of the site. In order to move the tanks along the East perimeter of the site to a position were the crane could lift them on to the respective flat bed trailers, the crane mount tractor was disconnected from its trailer and positioned near the northeast corner of the fenced in propane pumping station which was on the West side of the powerlines. The crane was used to drag the propane tanks from the East side to the West side of the powerlines. The employee was operating the crane while the coworker moved along with the tank being dragged. The crane's boom make contact with an exposed, energized powerline (14,400KV) and electrocuted the employee. the employee.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.180(h)(3)(iv) · Crawler locomotive and truck cranes
Serious$2,800$2,800Apr 15, 2016Final
Citation 1, item 2 Serious$1,700$1,700Apr 15, 2016Final
Citation 1, item 3a
29 CFR 1910.333(c)(3)(iii)(a) · Working near live electrical parts
Serious$4,900$4,900Apr 15, 2016Final
Citation 1, item 3b
29 CFR 1910.333(c)(3)(iii)(b) · Working near live electrical parts
Serious$4,900$0Apr 15, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.180 · Crawler locomotive and truck cranes

29 CFR 1910.184 · Slings

29 CFR 1910.184(d)

(d) Inspections. Each day before being used, the sling and all fastenings and attachments shall be inspected for damage or defects by a competent person designated by the employer. Additional inspections shall be performed during sling use, where service conditions warrant. Damaged or defective slings shall be immediately removed from service.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(c)(3)(iii)(a)

(iii) Vehicular and mechanical equipment. (A) Any vehicle or mechanical equipment capable of having parts of its structure elevated near energized overhead lines shall be operated so that a clearance of 10 ft. (305 cm) is maintained. If the voltage is higher than 50kV, the clearance shall be increased 4 in. (10 cm) for every 10kV over that voltage. However, under any of the following conditions, the clearance may be reduced:

29 CFR 1910.333(c)(3)(iii)(b)

(B) Employees standing on the ground may not contact the vehicle or mechanical equipment or any of its attachments, unless:

Other fuel dealers employers in Alabama

Alert subscribers get notified of each newly cited employer in Alabama the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.