Advanced Thermal Systems, Inc.: OSHA inspections and violations
Lancaster, New York · Other Metal Valve and Pipe Fitting Manufacturing · NAICS 332919
7inspections
23citation items
$13,604current penalties
Oct 30, 2024last inspection
Since 1981, OSHA inspectors have visited Advanced Thermal Systems, Inc. in New York 7 times.
The most recent inspection opened on Oct 30, 2024 as a planned inspection, in Lancaster.
In all, OSHA issued 23 citation items: 9 serious and 14 other-than-serious.
The proposed penalties came to $20,130; today they stand at $13,604, 32% less.
The rule cited most here is 1910.309 (), 3 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Advanced Thermal Systems, Inc. averages $8,469 across 1 cited inspection.
Advanced Thermal Systems, Inc. also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
New York · latest 90 days of OSHA records
353employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Advanced Thermal Systems, Inc. and get notified the morning OSHA posts a new citation for it.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Lancaster site logged 1 recordable injury or illness among about 33 workers: 3.0 per 100 full-time workers, against a median of 3.6 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Advanced Thermal Systems, Inc.
Lancaster · 2025
33
1
0
3.0
3.6
Included with any plan: 8 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.