OSHA SearchOSHA records by employer

Advanced Welding, LLC.: OSHA inspections and violations

Meriden, Connecticut · Structural Steel and Precast Concrete Contractors · NAICS 238120

8inspections
21citation items
$21,041current penalties
May 11, 2022last inspection

Since 2004, OSHA inspectors have visited Advanced Welding, LLC. in Connecticut 8 times.

The most recent inspection opened on May 11, 2022 after a complaint, in North Haven.

In all, OSHA issued 21 citation items: 20 serious and 1 other-than-serious.

The proposed penalties came to $26,137; today they stand at $21,041, 19% less.

The rule cited most here is 1926.760 (fall protection), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Advanced Welding, LLC. averages $4,045 across 2 cited inspections.

Advanced Welding, LLC.: OSHA citation items per year, 2004 to 2022
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

85employers cited

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch Advanced Welding, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345955090 OPENED MAY 11, 2022Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Jul 18, 2022

234 Universal Drive, North Haven, CT 06473 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342212321 OPENED MAR 29, 2017Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jan 30, 2018

1615 West Street, Southington, CT 06489 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.760(a)(1) · Fall protection
Serious$2,987$2,091Apr 6, 2017Final
Citation 2, item 1
29 CFR 1926.300(b)(1) · Tools—Hand and Power: general requirements
Other-than-serious$0$0Apr 6, 2017Final

Inspection 341504009 OPENED MAY 17, 2016Closed

Referral · Partial · Safety · 2 employees at the site · Closed Aug 8, 2017

850 Westfield Road 120 Stantack Road, Meriden, CT 06450 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,200$750Jul 14, 2016Final
Citation 1, item 1b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Jul 14, 2016Final
Citation 1, item 2a
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$2,000$1,300Jul 14, 2016Final
Citation 1, item 2b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Jul 14, 2016Final
Citation 1, item 3a
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Serious$2,000$1,300Jul 14, 2016Final
Citation 1, item 3b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Jul 14, 2016Final
Citation 1, item 4
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$1,200$750Jul 14, 2016Final
Citation 1, item 5
29 CFR 1926.758(d) · Systems-engineered metal buildings
Serious$2,800$1,900Jul 14, 2016Final

Inspection 339413254 OPENED SEP 12, 2013Closed

Complaint · Partial · Safety · 12 employees at the site · Closed Apr 11, 2016

718 Old Colony Road, Meriden, CT 06450 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(2)(ii) · Forklifts and other powered industrial trucks
Serious$2,000$2,000Nov 15, 2013Final
Citation 1, item 2
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$2,000$2,000Nov 15, 2013Final
Citation 1, item 3
29 CFR 1926.760(b)(3) · Fall protection
Serious$2,000$2,000Nov 15, 2013Final
Citation 1, item 4a
29 CFR 1926.761(b) · Training
Serious$1,200$1,200Nov 15, 2013Final
Citation 1, item 4b Serious$0$0Nov 15, 2013Final
Citation 1, item 5a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,000$2,000Nov 15, 2013Final
Citation 1, item 5b
29 CFR 1926.1060(a) · Ladder and stairway training
Serious$0$0Nov 15, 2013Final

Inspection 339441271 OPENED AUG 27, 2013Closed

Planned · Partial · Safety · 13 employees at the site · Closed Nov 18, 2014

1 Pucci Park, New Britain, CT 06051 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.502(d)(16)(iii) · Fall protection systems
Serious$2,000$1,000Oct 29, 2013Final

Inspection 336127782 OPENED AUG 28, 2012Closed

Complaint · Partial · Safety · 8 employees at the site · Closed Jul 22, 2013

50 River Lane, Deep River, CT 06417 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$2,000$2,000Sep 14, 2012Final
Citation 1, item 1b
29 CFR 1926.503(a)(2) · Fall protection training in construction
Serious$0$0Sep 14, 2012Final

Inspection 123157885 OPENED JUL 7, 2004Closed

Unprogrammed other · Partial · Safety · 6 employees at the site · Closed May 18, 2006

32 & 34 Plain St., Essex, CT 06426 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.760(b)(3) · Fall protection
Serious$750$750Jul 27, 2004Closed

Inspection 123290850 OPENED JAN 8, 2004Closed

Referral · Partial · Safety · 10 employees at the site · Closed Jan 9, 2004

1050 Main Street, Branford, CT 06405 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(2)(ii)

(ii) Training shall consist of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.758 · Systems-engineered metal buildings

29 CFR 1926.760 · Fall protection

29 CFR 1926.761 · Training

Other structural steel and precast concrete contractors employers in Connecticut

Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.