OSHA SearchOSHA records by employer

Advantage Fleet LLC dba Fleet Body Works: OSHA inspections and violations

Coopersville, Michigan · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance · NAICS 811310

1inspections
5citation items
$2,200current penalties
Apr 19, 2021last inspection

OSHA has inspected Advantage Fleet LLC dba Fleet Body Works once in Michigan.

The inspection began on Apr 19, 2021 after a complaint, in Coopersville.

That inspection ended with 5 citation items: 5 serious.

Penalties were first proposed at $4,400 and now stand at $2,200, 50% lower after settlements or reviews.

Flammable liquids comes up most often in these citations: 3 items under 1910.106.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Advantage Fleet LLC dba Fleet Body Works averages $2,200 (1 cited inspection).

Advantage Fleet LLC dba Fleet Body Works: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

621employers cited

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Advantage Fleet LLC dba Fleet Body Works and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345257158 OPENED APR 19, 2021Closed

Complaint · Partial · Health · 38 employees at the site · Closed Dec 9, 2021

920 O'malley Dr, Coopersville, MI 49404 · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$2,000$1,000Sep 20, 2021Final
Citation 1, item 1b
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$0$0Sep 20, 2021Final
Citation 1, item 2a
29 CFR 1910.106(e)(2)(iv)(c) · Flammable liquids
Serious$2,400$1,200Sep 20, 2021Final
Citation 1, item 2b
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$0$0Sep 20, 2021Final
Citation 1, item 2c
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$0$0Sep 20, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.106(e)(2)(iv)(c)

(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

Other commercial and industrial machinery and equipment (except automotive and electronic) repair and maintenance employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.